DM240XR High-Speed Digital Modulator
User Interfaces
TM120 – Rev. 1.1
4-7
DATA RATE (BPS):
Terrestrial Data Rate:
Enter in 1 Bps increments from 1,000,000 to
238,000,000 BPS.
SYMB RATE (SPS):
Output Symbol Rate:
Enter in 1 SPS increments from 1,000,000 to 68,000,000
Sps.
SPECTRUM:
{NORMAL, INVERTED}
ROLL OFF:
{0.35, 0.25, 0.20}
Changes the Spectrum Roll Off
PILOT SYMBOLS:
{ON, OFF}
Physical layer pilot symbols. Displayed only in DVB-S2
related network spec.
GOLD SEQ N:
{0 - 262142}
Gold code sequence index. Displayed only in DVB-S2.
LAST RATE CTRL:
{SYMBOL RATE, DATA RATE, AUTO}
Indicates the rate (symbol or data) that is maintained
when associated parameters (i.e. Modulation, Inner FEC
Code Rate, Terr Framing) are changed. For example, if
the Last Rate Control is set to “Symbol Rate” and the
modulation is subsequently changed, the system will
attempt to maintain the same symbol rate by adjusting
the data rate. If the Last Rate Control is set to “Data
Rate” and the modulation is subsequently changed, the
system will attempt to maintain the same data rate by
adjusting the symbol rate.
The “Auto” Setting of Last Rate Control causes the last
explicitly changed rate (symbol or data) to be maintained
when associated parameters are changed. For
example, if the last rate control is set to “Auto” and the
Data Rate is subsequently explicitly changed, any
subsequent changes to Modulation or Inner FEC Rate
would cause the symbol rate to be adjusted in order to
maintain the Data Rate.
4.2.3 Interface Menu Options and Parameters
4.2.3.1 Plug-In Interface Card (PIIC)
ACTIVE INPUT:
{INTFC 1, INTFC 2, INTFC 3}
Active Input Select - Allows the user to select the slot
that is active in Manual Mode.
PRIME INPUT:
{INTFC 1, INTFC 2, INTFC 3}
Prime Input Select - Allows the user to designate the
Prime Input in Redundancy Mode. An “(A)” indicates the
active input.
Summary of Contents for DM240XR
Page 2: ......
Page 10: ...Table of Contents DM240XR High Speed Digital Modulator x TM120 Rev 1 1 ...
Page 12: ...Introduction DM240XR High Speed Digital Modulator 1 2 TM120 Rev 1 1 ...
Page 16: ...Installation DM240XR High Speed Digital Modulator 2 4 TM120 Rev 1 1 ...
Page 19: ...DM240XR High Speed Digital Modulator Theory of Operation TM120 Rev 1 1 3 3 ...
Page 55: ...User Interfaces DM240XR High Speed Digital Modulator 4 36 TM120 Rev 1 1 ...
Page 67: ...Rear Panel Interfaces DM240XR DVB High Speed Digital Modulator 5 12 TM120 Rev 1 1 ...
Page 69: ...Maintenance and Troubleshooting DM240XR High Speed Digital Modulator 6 2 TM120 Rev 1 1 ...
Page 79: ...Technical Specifications DM240XR High Speed Digital Modulator 7 10 TM120 Rev 1 1 ...
Page 103: ...Appendix A DM240XR High Speed Digital Modulator A 24 TM120 Rev 1 1 ...
Page 124: ...DM240XR High Speed Digital Modulator Appendix B TM120 Rev 1 1 B 21 ...