background image

TerraWIN

 

Installation

 

Guide

 

DQ0266170/O.02

5

For

 

Norway

 

and

 

Sweden

 

only

Equipment

 

connected

 

to

 

the

 

protective

 

earthing

 

of

 

the

 

building

 

installation

 

through

 

the

 

mains

 

connection

 

or

 

through

 

other

 

equipment

 

with

 

a

 

connection

 

to

 

protective

 

earthing

 ‐ 

and

 

to

 

a

 

cable

 

distribution

 

system

 

using

 

coaxial

 

cable,

 

may

 

in

 

some

 

circumstances

 

create

 

a

 

fire

 

hazard.

  

Connection

 

to

 

a

 

cable

 

distribution

 

system

 

has

 

therefore

 

to

 

be

 

provided

 

through

 

a

 

device

 

providing

 

electrical

 

isolation

 

below

 

a

 

certain

 

frequency

 

range

 

(galvanic

 

isolator,

 

see

 

EN

 

60728

11).

Norway

Utstyr

 

som

 

er

 

koplet

 

til

 

beskyttelsesjord

 

via

 

nettplugg

 

og/eller

 

via

 

annet

 

jordtilkoplet

 

utstyr

 ‐ 

og

 

er

 

tilkoplet

 

et

 

kabel

TV

 

nett,

 

kan

 

forårsake

 

brannfare.

 

For

 

å

 

unngå

 

dette

 

skal

 

det

 

ved

 

tilkopling

 

av

 

utstyret

 

til

 

kabel

TV

 

nettet

 

installeres

 

en

 

galvanisk

 

isolator

 

mellom

 

utstyret

 

og

 

kabel

‐ 

TV

 

nettet

 

Sweden

Utrustning

 

som

 

är

 

kopplad

 

till

 

skyddsjord

 

via

 

jordat

 

vägguttag

 

och/eller

 

via

 

annan

 

utrustning

 

och

 

samtidigt

 

är

 

kopplad

 

till

 

kabel

TV

 

nät

 

kan

 

i

 

vissa

 

fall

 

medföra

 

risk

 

för

 

brand.

 

För

 

att

 

undvika

 

detta

 

skall

 

vid

 

anslutning

 

av

 

utrustningen

 

till

 

kabel

TV

 

ät

 

gal

vanisk

 

isolator

 

finnas

 

mellan

 

utrustningen

 

och

 

kabel

TV

 

nätet.

Unregulated

In

 

countries

 

where

 

the

 

radio

 

is

 

not

 

regulated

 

the

 

equipment

 

can

 

be

 

operated

 

in

 

any

 

regulation

 

configuration,

 

best

 

results

 

will

 

be

 

obtained

 

using

 

Universal

 

regulation

 

configuration.

Safety

 

Practices

Applicable

 

requirements

 

of

 

National

 

Electrical

 

Code

 

(NEC),

 

NFPA

 

70;

 

and

 

the

 

National

 

Electrical

 

Safety

 

Code,

 

ANSI/IEEE

 

C2,

 

must

 

be

 

considered

 

during

 

installation.

NOTES:

The

 

radio

 

devices

 

in

 

this

 

manual

 

have

 

been

 

approved

 

by

 

Industry

 

Canada

 

to

 

operate

 

with

 

the

 

antenna

 

types

 

listed

 

in

 

the

 

Certified

 

Antennas

 

appendix

 

with

 

the

 

maximum

 

permissible

 

gain

 

and

 

required

 

antenna

 

impedance

 

for

 

each

 

antenna

 

type

 

indicated.

 

Antenna

 

types

 

not

 

included

 

in

 

this

 

list,

 

having

 

a

 

gain

 

greater

 

than

 

the

 

maximum

 

gain

 

indicate

 

for

 

that

 

type,

 

are

 

strictly

 

prohibited

 

for

 

use

 

with

 

this

 

device.

 

Les

 

appareils

 

de

 

radio

 

dans

 

ce

 

manuel

 

ont

 

ete

 

approuves

 

par

 

Industrie

 

Canada

 

pour

 

fonctionner

 

avec

 

les

 

types

 

d’antenne

 

enumeries

 

à

 

l'annexe

 

Antennes

 

Certifiées

  

avec

 

le

 

gain

 

maximal

 

admissible

 

et

 

l’impedance

 

d’antenne

 

requise

 

pour

 

chaque

 

type

 

d’antenne

 

indique.

 

Types

 

d’antennes

 

non

 

inclus

 

dans

 

cette

 

liste,

 

ayant

 

un

 

gain

 

superieur

 

au

 

gain

 

maximum

 

indique

 

pour

 

ce

 

type,

 

sont

 

strictement

 

interdics

 

pur

 

une

 

utilisation

 

avec

 

cet

 

appareil.

 

Summary of Contents for TERRAWIN

Page 1: ...INSTALLATION GUIDE DQ0266170 O 02 TERRAWIN Release 1 0...

Page 2: ...k items to be installed 2 4 2 6 Prepare Tools 2 4 2 7 Install Standard Mounting Kit 2 5 2 7 1 Standard Mounting Kit 2 5 2 7 2 Pole 2 6 2 7 3 Wall 2 8 2 8 Mount Nodes 2 8 2 9 Mount the ODU S optional 2...

Page 3: ...TerraWIN Installation Guide DQ0266170 O 02 1 2 Appendix D Revision History...

Page 4: ...erved Each site usualy consists of 4 nodes radio units where each are installed pointing at right angles to the other 90 degrees so that all 4 cover 360 degrees1 Each of these nodes is called a Distri...

Page 5: ...TerraWIN Installation Guide DQ0266170 O 02 1 2 Basic Deployment Introduction Figure 1 1 Basic TerraWIN deployment A more detailed look at a site Figure 1 2 Nodes at Sites...

Page 6: ...oyment Introduction Some sites are on the sides or edges of the network segment and require only 3 nodes Figure 1 3 Three Nodes at side Sites Some sites are at the corners of the network segment and r...

Page 7: ...TerraWINRadio Unit Node The TerraWIN radio unit is shown below Both Distribution Nodes and Client Nodes are physically the same The difference between the two is in the software Figure 1 5 TerraWIN r...

Page 8: ...ply The TerraWIN Distribution Nodes can be supplied by either a PoE or by the ODU S Client Nodes are supplied by a PoE PoE Figure 1 7 PoE ODU S The TerraWIN ODU S is shown below Figure 1 8 TerraWIN Po...

Page 9: ...alling and aligning distribution and client nodes Connection to the nodes are via bluetooth Controller The Controller is a cloud based management application which manages a complete sector over a sin...

Page 10: ...izing Beam forming integrated antenna Enhanced interference mitigation capability Inter intra site sync to reduce self interference Regulations supported FCC ETSI Up to 15 Client Nodes per Distributio...

Page 11: ...ge 2 2 3 Configure Connectivity Parameters for Nodes in POP Site page 2 2 4 Check Connectivity to Nodes in POP Site page 2 4 5 Check items to be installed page 2 4 6 Prepare Tools page 2 4 Installatio...

Page 12: ...le play WINTouch only works on android smartphones 2 3 Configure Connectivity Parameters for Nodes in POP Site Do this in the depot before deploying on site This is only required for the Distribution...

Page 13: ...th Open WINTouch on your smartphone and follow its instructions to discover the node you have connected Figure 2 2 Connecting to node 2 3 3 Update Connectivity Parameters of Nodes Once you have establ...

Page 14: ...ping radio using node s new IP address 3 This is only needed for nodes in the POP Site Other nodes will be connected automatically by the Controller 2 5 Check items to be installed Nodes radio units...

Page 15: ...tribution Node requires a mounting kit Client Nodes can use a standard mounting kit or not depending on exactly where it is placed Each Distribution Node must be installed on a pole or wall 90o from e...

Page 16: ...nt to mount the device Once it is in place rotate the pole clamp as shown then tighten both bolts Thin Pole Dia 3 4 1 1 2 page 2 6 Medium Pole Dia 2 3 page 2 7 Thick Pole Dia 3 page 2 7 Figure 2 4 Con...

Page 17: ...olts Thick Pole 1 Diameter larger than 3 7 5cm Use worm drive clamps not supplied threaded through the holes as shown Figure 2 12 Mounting kit on a thick pole The pole clamp is not needed Figure 2 8 C...

Page 18: ...2 13 Mounting kit on a wall 2 8 Mount Nodes Each site typically has 4 Distribution Nodes In some cases for instance if a site is at the edge of the operational zone you may want to mount 3 or 2 nodes...

Page 19: ...TerraWIN Installation Guide DQ0266170 O 02 2 9 Mount Nodes Installation Steps Figure 2 15 Two Distribution Nodes mounted on a pole...

Page 20: ...TerraWIN Installation Guide DQ0266170 O 02 2 10 Mount Nodes Installation Steps Figure 2 16 Three Distribution Nodes mounted on a pole...

Page 21: ...TerraWIN Installation Guide DQ0266170 O 02 2 11 Mount Nodes Installation Steps Figure 2 17 Four Distribution Nodes mounted on a pole...

Page 22: ...stallation Guide DQ0266170 O 02 2 12 Mount the ODU S optional Installation Steps 2 9 Mount the ODU S optional The ODU S is shown mounted with four Distribution Nodes Figure 2 18 ODU S Mounted with 4 n...

Page 23: ...und Nodes Installation Steps 2 10 Ground Nodes Connect a ground cable to the indicated ground connection on the node as shown in the section below Figure 2 19 Ground connection on a Node 2 11 Ground t...

Page 24: ...the guidelines here We recommend using two lightning protection units LPUs for each node installation One near the node and one near the PoE The LPU can be mounted on a pole or on a wall Make sure th...

Page 25: ...and 3 Connect the grounding lug to a ground source 4 Remove the cable glands and thread the CAT 5e cables through them 5 Connect the cables to the LPU s sockets and the glands around the cables as sho...

Page 26: ...of the radio as shown Figure 2 21 Node input connection This connection provides power traffic and management connection 2 Add sealant tape to the connections see Waterproofing on page 2 18 3 Route th...

Page 27: ...ground connection 2 14 Connect PoE optional If you are not using the ODU S connect each Distribution Node via a PoE Client Nodes need a PoE in any event 6 Perform final connections via a PoE depending...

Page 28: ...o In port c Connect power cable 2 15 Waterproofing Protect all outdoor connections from rain dust moisture and salt by taping the cable gland connection with an appropriate sealant tape We recommend u...

Page 29: ...ations in the same manner To mount a Client Node See Mount Nodes on page 2 8 To connect a Client Node to power See Connect Node External Connections on page 2 16 2 17 Align Client Node Connect to the...

Page 30: ...de DQ0266170 O 02 2 20 Align Client Node Installation Steps Figure 2 26 Swivel horizontally b Repeat the above in elevation Figure 2 27 Swivel vertically c WINTouch will give an indication when the be...

Page 31: ...TerraWIN Installation Guide DQ0266170 O 02 2 21 Align Client Node Installation Steps d Once alignment is complete tighten the bolts holding the radio on the mounting kit Tighten bolts...

Page 32: ...where it is possible for people to stand or walk inadvertently in front of the antenna 3 2 2 Grounding All OEM_Name products should be grounded during operation In addition All radio units should be...

Page 33: ...pter supplied by OEM_Name Use the right tools Do not mount a radio unit upside down or horizontally Doing this may void you product warranty 3 2 5 Internal ESD Protection circuits OEM_Name equipment i...

Page 34: ...uaranteed resources See also CIR BFD Bidirectional Forwarding Detection A network protocol used to detect faults between two forwarding engines connected by a link CIR Committed Information Rate A lev...

Page 35: ...e public network itself GRE Tunnel A virtual point to point connection between two networks using the GRE protocol to carry this out HSC Hub Sync Client When using Hub Site Synchronization one unit is...

Page 36: ...orth SSM Synchronization Status Message Provides traceability of syn chronization signals and is used in the Synchronous Ethernet standard of communication Sync E or SyncE Synchronous Ethernet A stand...

Page 37: ...s Before proceeding to antenna installation details the following background information should be considered B 2 Considerations for Changing Antenna Parameters Let max Available Tx Power denote the m...

Page 38: ...tions The inequality above is always satisfied by the system in accordance with the relevant regulation The precise relationship between the items in inequality is as follows Required Tx Power per rad...

Page 39: ...FCC IC IDs on the label and refer to Table C 1 below FCC ID Q3K TRWN600G IC 5100A TRWN600G TerraWIN must be installed so as to provide a minimum separation distance from bystanders as specified in th...

Page 40: ...lation Guide DQ0266170 O 02 D 1 Appendix D Revision History Table D 1 Revision History TerraWIN Installation Guide DQ0266170 O 00 Cat No Date Description DQ0266170 O 02 May 2020 First revision for reg...

Page 41: ...tions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interferen...

Page 42: ...type Les unit s ext rieures et les antennes doivent tre install es UNIQUEMENT par des les professionnels de l installation qui connaissent le b timent et la s curit locaux codes et le cas ch ant sont...

Page 43: ...ts in the United States or where FCC rules apply only those antennas certified with the product are used The use of any antenna other than those certified with the product is expressly forbidden by FC...

Page 44: ...configurable by software to Tx power values other than those for which the product is certified it is the responsibility of the Professional Installer to restrict the Tx power to the certified limits...

Page 45: ...kabel TV t gal vanisk isolator finnas mellan utrustningen och kabel TV n tet Unregulated In countries where the radio is not regulated the equipment can be operated in any regulation configuration be...

Page 46: ...otector must be provided Refer to Articles 800 and 810 of the NEC for details 2 For protection of ODU against direct lightning strikes appropriate requirements of NFPA 780 should be considered in addi...

Page 47: ...TerraWIN Installation Guide DQ0266170 O 02 F 2 Other product names are trademarks of their respective manufacturers...

Page 48: ...com RADWIN Mexico Quinto 20 Col El Centinela Mexico DF O4450 Mexico Tel 52 55 5689 8970 Email salesmx radwin com RADWIN Peru Av Antares 213 Lima 33 Peru Tel 511 6285105 Fax 511 990304095 Email salesp...

Page 49: ...N Installation Guide DQ0266170 O 02 G 2 RADWIN South East Asia All Season Mansion 87 38 Wireless Road Lumpinee Bangkok 10330 Thailand Tel 66811707503 Email sales radwin com RADWIN Worldwide Offices Co...

Page 50: ...TerraWIN Installation Guide DQ0266170 O 02 1 Last page of EndPage files...

Reviews: