background image

 

39 

 

 

 

Indicator - IN/OUT cable 

 

 

 

 

Indicator 

– barcode scanner cable (LS2208) 

 

 

 

 

Indicator 

– PRINT, TARE, ZERO, STOP cable 

 

 

„Scale-Ethernet”  cable  is  a  standard  network  cable 
terminated with RJ45 connectors on both ends. 

Summary of Contents for PUE HX7

Page 1: ......

Page 2: ...2 JULY 2020...

Page 3: ...mage immediately unplug the device from the mains Scales to be decommissioned must be decommissioned in accordance with valid legal regulations Do not let battery discharge in case of prolonged storag...

Page 4: ...t 17 7 3 1 Numerical Box 17 7 3 2 Text Box 19 7 3 3 Diacritical Sign Table 20 7 3 4 Special Sign Table 21 7 4 Return to Weighing 21 8 INSTALLER INSTRUCTION 22 8 1 Connecting 6 Wire Load Cell 22 8 2 Co...

Page 5: ...by construction B Defining defects of unclear origin and means of their elimination can only be realized with the assistance of the manufacturer and the user representatives C RADWAG does not bear an...

Page 6: ...ing routine removal of small stains 1 Remove the dirt using cloth dipped in warm water 2 For best results add a little bit of dishwashing detergent 3 2 Cleaning ABS Components To clean dry surfaces an...

Page 7: ...7 4 MECHANICAL DESIGN 4 1 Dimensions PUE HX7 overall dimensions...

Page 8: ...P connector option 7 RS485 M12 8P connector option 8 Cable gland for a cable of a weighing platform 1 9 Cable gland for a cable of a weighing platform 2 option 10 ETHERNET RJ45 connector 11 USB connec...

Page 9: ...in5 GND Pin6 GND Pin7 24VDC Pin8 24VDC 4INPUTS Pin1 OUT1 Pin2 OUT2 Pin3 WY3 Pin4 OUT4 Pin5 COM Pin6 24VDC Pin7 GND Pin8 NC 4OUTPUTS Pin1 IN1 Pin2 IN2 Pin3 IN3 Pin4 IN4 Pin5 COM Pin6 24VDC Pin7 GND Pin...

Page 10: ...in5 COM Pin6 24VDC Pin7 GND Pin8 NC 4INPUTS Pin1 IN1 Pin2 IN2 Pin3 IN3 Pin4 IN4 Pin5 COM Pin6 24VDC Pin7 GND Pin8 NC 4 4 1 Technical Specifications Output parameters Output quantity 4 Output type Soli...

Page 11: ...4 4 2 I O Schematic Diagrams 4 inputs 4 outputs 4 5 Operation Panel Keys Press to switch the device on off Press to enter the main menu Press to log in Press to cancel the message Press to zero the sc...

Page 12: ...n screen button Programmable key assigned to an on screen button Programmable key assigned to an on screen button 4 6 Technical Specification Housing Stainless steel IP rating IP68 IP69 Display 7 colo...

Page 13: ...he air bubble takes central position 5 2 Start Up Plug the power cord to the mains Press key it is to be found at the top of the operation panel Upon completed start up the home screen is displayed au...

Page 14: ...y the following message Excessively discharged battery Scale shutdown is to occur Upon scale shutdown connect it to the mains in order to charge the battery 6 HOME SCREEN The home screen features 4 se...

Page 15: ...lt window provides all weighing related data 6 3 Workspace The workspace is to be found underneath the weighing result window The workspace comprises 4 programmable widgets Each working mode features...

Page 16: ...that operate as arrow keys Menu view 7 2 Menu Keys Press to enter the main menu Press to go to the home screen Press to go back or to discard entering parameter modifications Press to go back Press to...

Page 17: ...e it by one digit down 7 3 Entering Numbers Text The software features two different edit boxes numerical box for entering part mass values tare values etc text box for entering printout template univ...

Page 18: ...r a few seconds long press Press to enter digit 6 Press to enter digit 7 Press to enter digit 8 Press to enter digit 9 Press to enter digit 0 Press to enter dot hold the key for a few seconds long pre...

Page 19: ...case character mode digit mode arrow keys operation bottom bar operation Press to save the project to lb file on a USB flash drive Press to read the project saved to lb file on a USB flash drive Pres...

Page 20: ...move the cursor down long press Press to enter w x y z Press to activate Caps Lock function long press Press to enter space sign Press to enter sign dot long press Press to go to the next line in the...

Page 21: ...ate special signs table while editing text box it is necessary to press and hold key Where Function inactive Press to switch to diacritical sign keyboard 7 4 Return to Weighing Introduced modification...

Page 22: ...scales 8 1 Connecting 6 Wire Load Cell Connect 6 wire load cell to the main board following the diagram below 6 wire load cell connection Load cell junction J14 Load cell signals NOTES REF SENSE JP6 n...

Page 23: ...d cell signals Notes REF JP6 soldered REF JP5 soldered IN OUTPUT IN OUTPUT 5V INPUT AGND INPUT 8 3 Connecting Load Cell s Cable Shield To ensure correct scale operation follow below instructions regar...

Page 24: ...INT C Point C threaded pin galvanically connected with an indicator housing for fixing of a ring terminal E solder pad on DP4 module 9 FACTORY SETUP To access and modify factory settings and parameter...

Page 25: ...a in a top bar of the home screen Scale name Special name and or name of RADWAG distributor s device 15 characters maximum Value entered here replaces the set Scale type value Platform quantity 1 1 2...

Page 26: ...0 02 0 05 0 1 0 2 0 5 1 2 5 10 20 50 Verification units for Range 2 none value unverified version Digit marker None None 1 2 3 Setting quantity of digits counting from the last digit of the displayed...

Page 27: ...instrument adjustment menu External adjustment Scale adjustment refer to section 9 6 1 Start Mass Determination Start mass determination refer to section 9 6 2 Start mass 100 Current start mass expres...

Page 28: ...5 Scale Defining Defining the device at the production stage requires entering basic scale parameters serial number weighing device type Procedure Enter Global Scale defining submenu message Continue...

Page 29: ...justment Please wait is displayed Upon adjustment completion message Remove weight is displayed Unload the weighing pan the weighing device displays the Adjustment submenu The adjustment of additional...

Page 30: ...isplayed window Upon result stabilization press key to confirm Mass edit box is displayed again second linearity correction point Linearity correction process for the 2nd point is analogous to the lin...

Page 31: ...ates changes of gravity force being a result of different latitude It allows to carry out correct scale calibration adjustment away from the point of subsequent use The gravity correction value must b...

Page 32: ...sing indicator menu For 12IN 12OUT module the indicator s housing cover features two cable glands through which 3 meter long leads terminated with strip wires are fed 10 1 1 Technical Specifications O...

Page 33: ...nals Overview Signals transmitted via 16 x 0 5 mm2 cable with numbered wires INPUTS OUTPUTS Wire number Signal Wire number Signal 1 IN1 1 OUT1 2 IN2 2 OUT2 3 IN3 3 OUT3 4 IN4 4 OUT4 5 COMM1 5 COMM1 6...

Page 34: ...utput module 10 2 1 AN Module Configuration The module s working mode is set using S1 switch when setting the module s working mode refer to the below table Analog outputs module board provides descri...

Page 35: ...30V DC max 40mA 10 2 3 AN Module Diagrams of Connection Cables Voltage output wiring diagram WIRE COLOURS Colour Signal pink UOUT grey GND yellow 24V DC green GND Current output wiring diagram WIRE C...

Page 36: ...aximum load cell impedance 1200 Load cell power supply 5V Load cell wiring 4 or 6 wires shield Multi range option YES 10 3 2 Colours of Weighing Platform s Signal Wires Markings RADWAG Colour Marking...

Page 37: ...5Rxxxx board ver A Position of PROFIBUS module on 385Rxxxx board ver A The indicator is equipped with input and output connectors On the output connector there is 5 VDC voltage this provides correct o...

Page 38: ...38 11 DIAGRAMS OF CONNECTION CABLES Indicator computer cable Indicator printer cable ZEBRA Indicator printer cable EPSON...

Page 39: ...39 Indicator IN OUT cable Indicator barcode scanner cable LS2208 Indicator PRINT TARE ZERO STOP cable Scale Ethernet cable is a standard network cable terminated with RJ45 connectors on both ends...

Page 40: ...40 12 ERROR MESSAGES...

Page 41: ...41...

Reviews: