background image

 

 

 

Manual number: 
LMI-42-04/07/11/ENG 

 

 

 

 

 

 

 

                                                           DJ-03

 

Antistatic Ionizer 
DJ-02                                                  
DJ-03 

 

 
 

DJ-02

 

 
 
 
 

 

 

 

 

                                                                                                                                   

 

 

M A N U F A C T U R E R  
O F   E L E C T R O N I C   W E I G H I N G   I N S T R U M E N T S  

RADWAG 26 – 600 Radom, Bracka 28 Street, POLAND 
phone +48 48 38 48 800, phone/fax. +48 48 385 00 10 
Sales Depa48 48 366 80 06 

www.radwag.com 

 
 

Summary of Contents for DJ-02

Page 1: ... Ionizer DJ 02 DJ 03 DJ 02 M A N U F A C T U R E R O F E L E C T R O N I C W E I G H I N G I N S T R U M E N T S RADWAG 26 600 Radom Bracka 28 Street POLAND phone 48 48 38 48 800 phone fax 48 48 385 00 10 Sales Department 48 48 366 80 06 www radwag com ...

Page 2: ... 2 JULY 2011 ...

Page 3: ...ATA 4 3 BASIC SAFETY PRECAUTIONS 5 4 CONSTRUCTION OF IONIZER DJ 02 I DJ 03 7 5 UNPACKING 7 5 1 Unpacking 7 6 STARTING 7 6 1 Work modes 8 7 MAINTENANCE SERVICE UTILIZATION 9 7 1 Maintenance 9 7 2 Service 9 7 3 Utilization 9 8 CONFORMITY CERTIFICATE 10 ...

Page 4: ...nces attraction or repulsion of elements which are in small distances to each other It is usual for non conducting materials plastic glass Some of the elements of balance are made of plastic and glass This problem can affect the balances Usually this problem appears as multiply repeatability error or as multiply error of indications 2 TECHNICAL DATA Distance sample ions source about 5 50cm Source ...

Page 5: ... ionizer using The room where ionizer is used should be ventilated properly If ionizer was kept in lower temperature than temperature of place of its working the ionizer should be left for 2 hours until it reaches temperature stabilization before it is used In the other case moisture condensation on ionizer can occur and as a result electric shock Do not touch ions sources in case of danger of ele...

Page 6: ...ed voltage see data plate should be the same as power voltage The ionizer can be wired to the socket with bolt only If the ionizer is not used it should be switched off power supply Any repair should be made by Radwag service only ATTENTION Damaged ionizer cannot be connected to power supply It can cause electric shock or fire It is not allowed to use ionizer in vehicles or outside If any damage o...

Page 7: ...5 UNPACKING 5 1 Unpacking Unpack the ionizer and remove protective foams Take the ionizer out off the box and put it in place of usage very carefully 6 STARTING Air ionizer start up requires plugging it to the mains and setting the main switch key to position ON The main switch key is located on housing of high voltage generator Switching on the air ionizer is signalled by a glowing diode of the m...

Page 8: ...arization alternately In each of work modes intensity of ionization can be changed Work modes and intensity of ionization is presented on figure below forward bias convertible polarization minus polarization max intensity of ionization medium intensity of ionization min intensitiy of ionization ...

Page 9: ...th and gentle alcohol detergent 7 2 Service Only service Radwag are allowed to open repair and modificate construction of ionizer It is recommended to make technical check up after 500hours of work and to change ions sources after 10 000 hours of work 7 3 Utilization Utilization of ionizer and package must be processed in accordance with legal regulations valid in a country where the ionizer is us...