18
SCOPIA 400 Platform Guide
Electrical Safety
G
ROUNDING
The power cable of the SCOPIA 400 platform should only be connected to a
power outlet that has a protective earth contact. Do not use an extension cord
that does not have a protective conductor (ground). The SCOPIA 400 chassis
can become dangerous if you interrupt any of the protective conductors
(grounding) or disconnect any of the protective earth terminals.
Caution
For North American installations, select a 3-conductor (18 AWG)
power supply cord that is UL listed and CSA certified. The cord must be
terminated in a molded-on plug cap rated 125V/5A, with a minimum length of
1.5m (6 feet) and no longer than 4.5m (approximately 14 feet).
Caution
This is a class I unit. In Denmark, use this unit with an AC cord suited
to Danish specifications. The cord should include an earthing conductor. Plug the
unit into a wall socket outlet which is connected to the protective earth contact. Do
not use socket outlets which are not connected to a protective earth contact!
Varoitus
Laite on liitettävä suojamaadoituskoskettimilla varustettuun
pistorasiaan.
Advarsel
Apparatet må tilkoples jordet stikkontakt.
Varning
Apparaten skall anslutas till jordat uttag.
H
IGH
V
OLTAGE
Disconnect the SCOPIA 400 chassis from the power line before removing the
cover. Avoid any adjustment, maintenance, or repair of an opened chassis under
voltage. These actions should only be carried out by a skilled person who is
aware of the dangers involved. Capacitors inside the chassis may still be
charged, even if the unit has been disconnected from the power source.
P
OWER
S
UPPLY
Caution
Risk of electric shock and energy hazard. Disconnecting one power
supply disconnects only one power supply module. To isolate the unit completely,
disconnect all power supplies.
Summary of Contents for SCOPIA 400
Page 1: ...SCOPIA 400 Platform Guide...
Page 6: ...vi SCOPIA 400 Platform Guide...
Page 8: ......
Page 14: ...6 SCOPIA 400 Platform Guide SCOPIA 400 Chassis Power Supply...
Page 20: ...12 SCOPIA 400 Platform Guide Circuit Switch Network Port...
Page 34: ...26 SCOPIA 400 Platform Guide Prevention des Decharges Electrostatiques...