IN095 Rev B 0718
7
3 Saber Way, Ward Hill, MA 01835 | radonaway.com
Typical CFM Vs. Static Pressure “WC
1.0”
1.5”
2.0”
2.5”
3.0”
3.5”
4.0”
GP201
54
42
11
-
-
-
-
GP301
64
54
41
4
-
-
-
GP401
-
61
52
44
22
-
-
GP501
-
-
66
58
50
27
4
Model
Size
Weight
Inlet/Outlet
GP201
13”H x 12.5” Dia.
12 lbs
3.5”OD (3.0” PVC Sched 40 size compatible)
GP301
13”H x 12.5” Dia.
12 lbs
3.5” OD
GP401
13”H x 12.5” Dia.
12 lbs
3.5” OD
GP501
13”H x 12.5” Dia.
12 lbs
3.5” OD
Model
Power Consumption
120VAC, 60Hz, 1.5 Amp Maximum
Maximum Recommended Operation Pressure*
(Sea Level Operation)**
GP201
31-65 watts
1.8” WC
GP301
56-100 watts
2.3” WC
GP401
62-128 watts
3.0” WC
GP501
68 - 146 watts
3.8” WC
*Reduce by 10% for High Temperature Operation **Reduce by 4% per 1000 ft. of altitude.
GP Series Product Specifications
Typical CFM Vs. Static Pressure “WC
Model
0”
.25”
.5”
.75”
1.0”
1.25”
1.5”
1.75”
2.0”
RP140
135
103
70
14
-
-
-
-
RP145
166
146
126
104
82
61
41
21
3
RP260
251
209
157
117
70
26
-
-
-
RP265
375
330
282
238
204
170
140
108
70
RP380
531
490
415
340
268
200
139
84
41
Model
Recommended Duct
PVC Pipe Mounting
Thermal Cutout
Insulation Class
RP140
3” or 4” Schedule
20/40 PVC
Mount on the duct pipe or with
optional mounting bracket.
For Ventilation: 4”, 6” or 8” Rigid
or Flexible Ducting.
130
o
C/266
o
F
Class B Insulation
RP145
130
o
C/266
o
F
Class F Insulation
RP260
150
o
C/302
o
F
RP265
150
o
C/302
o
F
RP380
6” Schedule 20/40 PVC Pipe
150
o
C/302
o
F
XP151
3” or 4” Schedule
20/40 PVC
Fan may be mounted on the duct
pipe or with integral flanges.
120
o
C/248
o
F
Class B Insulation
XP201
GP201
3” or 4” Schedule
20/40 PVC
Fan may be mounted on the duct
pipe or with integral flanges.
120
o
C/248
o
F
Class B Insulation
GP301
GP401
GP501
RP, XP and GP Series Additional Specifications
Continuous Duty
3000 RPM
Thermally Protected
RP, GP Residential and Commercial
XP Residential Only
Rated for Indoor or Outdoor Use