PROMENTUM™

SWITCH AND CONTROL MODULE 

INSTALLATION GUIDE

ATCA-2210

This document describes how to install and to set up the 
Promentum™ ATCA-2210 switch and control module 
(SCM). 

Obey ESD precautions

W

ARNING

Obey the electrostatic discharge (ESD) 

procedures described at 

www.radisys.com

 when you install 

the product. 
Electrostatic discharge can cause permanent damage to 

static-sensitive components in this product. Important ESD 
procedures include: 

ƒ

Keep the product in its ESD shielding bag until a step 

tells you to remove it.

ƒ

Put on a grounded wrist strap before you move near or 

touch the product.

ƒ

Install the product only in a grounded work area.

 

Prepare for installation

The installation of the SCM requires the following:

ƒ

An AdvancedTCA® (ATCA®) shelf, such as a RadiSys 
ATCA-6000, ATCA-6006, ATCA-6014, or ATCA-6016 
shelf

ƒ

A 9-pin D-shell to RJ-45 serial port cable (shipped 
with the SCM)

ƒ

A standard crossover Ethernet cable

ƒ

Adequate ventilation for the shelf 

Install SFPs or XFPs on the SCM

The SCM comes with sockets for small form-factor 
pluggable (SFP) and 10 Gigabit small form-factor 
pluggable (XFP) transceiver modules. If SFPs and XFPs 
are installed, they can provide external connections to the 
Ethernet interfaces. The sockets are accessed from the 
faceplate of the SCM.

007-02524-0004 • September 2008
Copyright © 2006-2008 by RadiSys Corporation. All rights reserved. 
RadiSys is a registered trademark and Promentum is a trademark of RadiSys Corporation. Linux is a registered trademark of Linus Torvalds. AdvancedTCA and ATCA are 

registered trademarks of PCI Industrial Computer Manufacturers Group. Procomm Plus and Symantec are registered trademarks of Symantec Corporation. All other 

trademarks, registered trademarks, service marks, and trade names are the property of their respective owners.

Summary of Contents for PROMENTUM ATCA-2210

Page 1: ...14 or ATCA 6016 shelf A 9 pin D shell to RJ 45 serial port cable shipped with the SCM A standard crossover Ethernet cable Adequate ventilation for the shelf Install SFPs or XFPs on the SCM The SCM comes with sockets for small form factor pluggable SFP and 10 Gigabit small form factor pluggable XFP transceiver modules If SFPs and XFPs are installed they can provide external connections to the Ether...

Page 2: ...e adequately grounded 2 Remove the transceivers and the SCM from their antistatic bags 3 On the SCM s faceplate remove the filler plugs from the sockets in which you are installing the SFP or the XFP transceivers For sockets not being used keep the filler plugs in place to protect the internal components of the board 4 Make sure the transceiver s bale the latch on the cable side of the transceiver...

Page 3: ...side is on the left and the flat smooth side is on the right If the SCM is oriented horizontally insert the filler plug so the recessed side is on the bottom and the flat smooth side is on the top SFP filler plug installation If the SCM is oriented vertically insert the filler plug so the connector side and retaining clip are on the left If the SCM is oriented horizontally insert the filler plug s...

Page 4: ...stallation of the SCM in the non RadiSys shelf you must disable the SCM s on board Shelf Manager 1 Install the SCM in the shelf on page 5 2 Disable the Shelf Manager on the SCM on page 10 3 Verify switch operation on page 7 ____ ____ ____ Removed from a non RadiSys shelf and reinstalled in a RadiSys shelf Pre removal configuration required Before you remove the SCM from the non RadiSys shelf you m...

Page 5: ...the SCM If the SCM does not slide easily make sure you are inserting the SCM into the correct slot and that it is aligned properly 5 Once the SCM is inserted all the way into the shelf simultaneously close both ejector latches inward This seats the SCM s connectors into the shelf s backplane The hot swap H S LED light flashes until the SCM is fully powered Once powered the LED light turns off If t...

Page 6: ... the prompt 5 Verify that you receive a welcome message and a prompt showing ATCA 2210 Important If the SCM has been installed in a non RadiSys shelf you may receive a DEBUGMODE prompt rather than the ATCA 2210 prompt If this occurs disable the SCM s on board Shelf Manager See Disable the Shelf Manager on the SCM on page 10 for more information Connect to the Ethernet maintenance port 1 Connect a ...

Page 7: ...e enabled If needed press the space bar to view more of the list 4 Proceed to the applicable section or step To enable all ports see Enable all ports on page 8 To enable only specific ports see Enable specific ports on page 8 To leave all ports disabled continue with step 5 5 Enter the exit command to return to the ATCA 2210 prompt If you are asked to save changes enter y for yes or n for no If yo...

Page 8: ...up configuration Note If the SCM includes the optional Procelerant CE3100 COM Express module you may need to perform some additional port configuration procedures See the ATCA 2210 Switch and Control Module Reference for more information 3 Enter the exit command to return to the ATCA 2210 prompt 4 Enter the exit command to log off the SCM 5 If you have two SCMs installed repeat these steps on the ...

Page 9: ...s configuration is saved as the startup configuration Base Ethernet switch interfaces ATCA 6000 backplane slots s 0 p 1 6 9 14 ATCA 6006 backplane slots s 0 p 3 6 ATCA 6014 backplane slots s 0 p 1 6 9 14 ATCA 6016 backplane slots s 0 p 1 7 10 16 Front panel optical s 1 p 5 9 Internal ports s 2 p 1 3 4 RTM s 3 p 5 8 or p 5 6 depends on SCM configuration Base Ethernet switch internal ports 2 1 The l...

Page 10: ...s command to exit the platform management CLI exit 5 If you have two SCMs installed repeat these steps on the other SCM Disable the Shelf Manager on the SCM By default the SCM is configured to function in a RadiSys shelf For an SCM to operate in a non RadiSys shelf you must disable the Shelf Manager on the SCM 1 Connect the included serial port cable by plugging one end into the RJ 45 serial port ...

Page 11: ... Enter ShMC Mode Enable 0 Disable 1 Enter 1 to disable the on board Shelf Manager The menu prompt displays upon completion of the process 13 To verify the on board Shelf Manager is disabled enter 41 14 The following text displays Get SCM ShMgr Mode Enter address in hex Enter the same host address you entered for step 11 If the on board Shelf Manager is disabled this message displays SCM ShMgr Mode...

Page 12: ...e Enter key and verify you get a login prompt Enter root at the prompt 5 To determine the version of SCM s on board Shelf Manager enter the following at the ATCA 2210 prompt resys_debug h 6 After determining the version number enter the appropriate command 7 Once the software tool has completed its initialization the host address is displayed Make a note of this address for an upcoming step Typica...

Page 13: ...hip with a factory installed basic software package Once the SCM is installed and depending on your organization s needs you may choose to change the BIOS setting or install an operating system and drivers See the ATCA 2210 Switch and Control Module Reference for instructions on performing such procedures Where to go from here See the ATCA 2210 Switch and Control Module Reference for detailed info...

Page 14: ...sit the RadiSys Web site at www radisys com for product information and other resources Downloads manuals release notes software etc are available via the Technical Support Library product links at www radisys com support or the product pages at www radisys com products ...

Reviews: