Programming Interface
Page 29
4
4
Result Codes:
OK
n=0,1,2
Error
Otherwise
Yn
Select Stored Profile on Powerup
This command selects which user profile will be recalled into the active profile
(powerup).
&Y0
Recall user profile 0 on powerup.
&Y1
Recall user profile 1 on powerup.
Result Codes:
OK
n=0,1.
Error
Otherwise.
Zn=x Stored Telephone Number
This command is used to store up to four telephone numbers. The maximum number
of digits per number is 36.
x = 0-9, A, B, C, D, #, *, T, P, R, W, @, comma, !, ; (dial string).
n = 0-3.
AT% Commands
%An Set Auto-reliable Fallback Character
This command allows the user to specify the character that tells the modem to return
(or fall back) from auto-reliable (MNP) mode to a normal connection on the
answering modem.
Result Codes:
OK
n = 0-127 (ASCII character).
Error
Otherwise.
Default
013.