EXM-31 Hardware Reference
Page 2
1
1
•
One of the following options:
⎯
Classic A: Hayes
Auto Sync
⎯
Classic B: Class 2 (August 1990) Fax Interface
•
Integrated 550 UART emulation
Note that there are two versions of this product: on is for international markets, and
the other is a U.S. version. This is a build-time option.
Specifications
Table 1 defines the environmental and electrical specifications of the EXM-31.
Characteristic
Value
Environmental
Temperature operating
0
°
to 60
°
C (* see below)
storage
-40
°
to 85
°
C
Humidity
operating
5% - 95% (non-condensing)
storage
5% - 95% (non-condensing)
Vibration operating .015"displacement with 2.5 g peak (max)
acceleration over 5 to 2000 Hz
storage
.030" displacement with 5 g peak (max)
acceleration over 5 to 2000 Hz
Shock
operating
30g 11 msec duration, half-sine shock
pulse
storage
50g 11 msec duration, half-sine shock
pulse
Electrical
Current
maximum
5V @ 700 mA
typical
5V @ 500 mA
Table 1. EXM-31 Environmental and Electrical Specifications.
* Upper temperature limit degrades 2
°
C per 1000 ft. elevation. Maximum
elevation 10,000 ft.