D9412G/D7412G Operation & Installation Guide
© 2002 Radionics
Page 13
43488D
D9412G/D7412G
Overview
2.0
Overview
Figure 1: System Configuration
2.1
D9412G/D7412G Differences
The table below provides an overview of the differences between the D9412G and D7412G panels.
Table 3: Differences Between the D9412G and D7412G
New Features
D9412G
D7412G
Access Control
YES, 8 Doors
YES, 2 Doors
Expanded Users
Arm/Disarm Passcodes
Cards/Tokens
249
996
99
396
Passcode-Protected Custom
Functions
16
4
Number of Printers
3
1
Number of Points
246
75
Number of Relays
128
64
Use command centers and/or keyswitches to arm the
panel by area. Each panel can have up to eight areas.
Each area can have its own account number or areas
can be grouped together with a common account
number. Points of protection are assigned to areas.
Control/
Communicator
On-Board Points
1 to 8
D9131A Module connects
to a parallel printer to print
the event log.
D928 Module allows the panel
to monitor two phonelines.
D8129 OctoRelay provides alarm
and auxilliary relay output.
(Other functions available.)
D9210B Modules may be
used for access control.
D8125 or D8125MUX Interface
used for point expansion.
Each D8128D OctoPOPIT combines
eight POPIT points in one module.
D8132 Modules (two 12 VDC, 7Ah batteries)
provide additional power for command
centers and other powered devices.
D9133TTL-E allows
communication over
a Local or Wide Area
Network