background image

D9412G/D7412G

Control/Communicators

Operation and Installation Guide

Summary of Contents for D9412G

Page 1: ...D9412G D7412G Control Communicators Operation and Installation Guide...

Page 2: ...D9412G D7412G Operation Installation Guide 43488D Page 2 2002 Radionics D9412G D7412G Notes...

Page 3: ...Communicator 16 2 4 4 Command Centers 17 2 4 5 Keyswitch 17 2 4 6 Access Control 17 2 4 7 Event Memory 17 2 4 8 Event Log 17 2 4 9 EMI Lightning Transient Protection 18 2 4 10 Programming 18 2 4 11 O...

Page 4: ...rcuit Protection 29 5 2 Total Available Power 29 5 3 Continuous Power Outputs Terminals 29 5 3 1 Continuous Current Draw 29 5 4 Programmable Power Outputs Terminals 29 5 4 1 Programming 29 5 4 2 Optio...

Page 5: ...Expansion Loops to POPEX Modules 43 8 3 5 POPIT Sensor Loops 43 8 3 6 POPIT Module Point Assignments 43 8 3 7 Program Record Sheet 43 8 4 D8128D OctoPOPIT Module 44 8 4 1 Description 44 8 4 2 Listing...

Page 6: ...le 59 11 6 1 1 Connecting the D9133DC 59 11 6 1 2 Used as an External Modem 59 11 6 2 D9133TTL E Network Interface Module 59 11 6 3 Address Settings 59 11 6 4 Supervision 59 12 0 Programmer and Access...

Page 7: ...el 40 Figure 14b Connecting the D8125 POPEX to the D7412G Panel 41 Figure 15 Program Record Sheet 44 Figure 16a Connecting D8128D OctoPOPITs to the D9412G 47 Figure 16b Connecting D8128D OctoPOPITs to...

Page 8: ...7 Charging Status and Low Battery LEDs 28 Table 8 Data Expansion Loop Wire Specifications 42 Table 9 D8128D OctoPOPIT Switch Settings for D9412G D7412G 46 Table 10 D8129 OctoRelay Switch Settings 49...

Page 9: ...s plus the status and battery LEDs 4 Power Supply provides information on the primary and secondary modules and instructions on connecting and programming them 5 Power Outputs provides information on...

Page 10: ...ourier Text Text that appears like this indicates what may appear on the D5200 Programmer display command center keypad or internal printer CAPITALIZED TEXT Text like this is used to indicate to the u...

Page 11: ...jack The ringer equivalence number REN is used to determine the number of devices that may be connected to the telephone line Excessive RENs on the telephone line may result in the devices not ringin...

Page 12: ...D9412G D7412G Operation Installation Guide 43488D Page 12 2002 Radionics D9412G D7412G Introduction Notes...

Page 13: ...rm the panel by area Each panel can have up to eight areas Each area can have its own account number or areas can be grouped together with a common account number Points of protection are assigned to...

Page 14: ...put 2 0 A maximum at 10 2 VDC to 13 9 VDC output Output may be steady or one of three pulsed patterns depending on programming See Relays in the D9412G D7412G Program Entry Guide Switched Aux Power 1...

Page 15: ...2C D192D D268 D269 D279A D442 D448 D449 D720 D720R D720W D928 D1218 D1255 D1255R D1255W Dual Battery Harness Powered Loop Interface Module 12 V 7 Ah Rechargeable Battery Reversing Relay Dual Class A I...

Page 16: ...control panels can be monitored on the network for their status 2 4 Standard Features 2 4 1 Points The Radionics D9412G Control Communicator panel provides up to 246 points of protection and the D7412...

Page 17: ...o access doors with up to 396 uniquely identified cards tokens Access can be granted from a Wiegand style access control device card reader connected to the D9210B Access Control Interface Module Acce...

Page 18: ...nt Manager RAMIV Fire Alarm Verification Programmable Alarm Output Programmable Relay Output using the D8129 OctoRelay Module Opening and Closing Windows Skeds scheduled events 2 4 12 Control Communic...

Page 19: ...ntrol Communicators for Central Station Local Police Connect Bank Safe and Vault Mercantile Safe and Vault and Grade A Household systems Access Control and Proprietary Department of Defense DOD The D9...

Page 20: ...D9412G D7412G Operation Installation Guide 43488D Page 20 2002 Radionics D9412G D7412G Overview Notes...

Page 21: ...tion of the D5200 Programmer or the Remote Account Manager RAM IV 3 2 Enclosure Options Mount the control communicator assembly in any of the Radionics enclosures listed below Refer to the D9412G D741...

Page 22: ...Entry Guide When the jumper is in the unlocked open position the panel will not detect ground fault conditions If a ground fault condition occurs the command centers will display SERVC GND FAULT and t...

Page 23: ...iption of these events Always touch Terminal 10 the panel s earth ground connection before beginning work on the panel 3 6 2 Install and Wire Detection Devices Install and wire detection devices and c...

Page 24: ...must be installed for fire or combined fire burglary systems using verification points Use the D9412G D7412G Program Record Sheet to gather the information needed to fill out the point chart Install...

Page 25: ...ctors including the transformer wire Route data wiring away from AC and phone wiring Connect the battery and then plug in the transformer Radionics recommends that the battery always be connected firs...

Page 26: ...START GND START GROUND START 12 11 13 Point 1 Point 2 GROUND START Requires Relay D136 in Ground Start Socket Battery Wires To Batteries To ensure proper spacing secure wires using Tie Wraps or simil...

Page 27: ...he discharge continues the panel becomes inoperative when the battery voltage drops below 10 2 VDC 4 2 5 Battery Charging Circuit Float Charge The float voltage for the battery charging circuit is 13...

Page 28: ...ttery is missing shorted or reversed The Charging Status LED is off but the red Low Battery LED is flashing Yellow On Battery float charge is below 13 8 VDC If AC is present the battery is charging Wh...

Page 29: ...al 32 Power Use this terminal to power SDI Serial Device Interface devices such as command centers the D9131A Parallel Printer Interface Module and the D9210B WiegandTM Control Interface Module Access...

Page 30: ...ls 6 and 7 to power bells siren drivers piezo fire sounders electronic horns or other devices Programming determines the format of the output and the conditions that activate it One PTC protects Termi...

Page 31: ...r One self resetting circuit breaker protects Terminals 6 7 and 8 against shorts Verification Reset Relay The default program sets Relay C Terminal 8 as a verification reset relay See Relay Parameters...

Page 32: ...D9412G D7412G Operation Installation Guide 43488D Page 32 2002 Radionics D9412G D7412G Power Outputs Notes...

Page 33: ...ure See Figure 8 Install the jack on the street side of the phone switch wired ahead of any PBX equipment Line seizure provides for a temporary interruption of normal phone usage while the communicato...

Page 34: ...o test the status of the phone line In some instances a given telephone line may be out of service without affecting the voltage on the line The phone line monitor can not recognize this trouble condi...

Page 35: ...ines The panel monitors both lines If a signal is generated and the panel senses that a line is bad then it will attempt to use the other phone line to send the message If trouble is detected the pane...

Page 36: ...6 12 5 D928 Status LEDs Four LEDs mounted on the front edge of the D928 Module show the status of AC power for the panel the status of the two phones lines and communication failure See Figure 11 When...

Page 37: ...across the point input terminal and one of the common terminals The sensor loops must be connected and the 1 k end of line resistor in place Open Loop Greater than 3 7 VDC but less than 5 0 VDC Norma...

Page 38: ...y Positive Are Inherently Power Limited Requirements For Battery Standby Time May Reduce Allowable Output CAUTION See Manual For Power Requirements Relating to Terminals 6 7 WARNING Multi Battery Inst...

Page 39: ...BLE report The panel sees all points on the shorted expansion loop as shorted and responds according to point programming except for fire points The fire points will respond locally as a trouble condi...

Page 40: ...D9412G D7412G Operation Installation Guide 43488D Page 40 2002 Radionics D9412G D7412G Off board Points Figure 14a Connecting the D8125 POPEX to the D9412G Panel...

Page 41: ...D9412G D7412G Operation Installation Guide 2002 Radionics Page 41 43488D D9412G D7412G Figure 14b Connecting the D8125 POPEX to the D7412G Panel Off board Points...

Page 42: ...of the D8125 POPEX Module to ZONEX OUT 1 Terminal 28 4 Connect the AUX terminal of the D8125 to Terminal 24 on the D9412G or to Terminal 3 on the D7412G For Point numbers from 129 to 247 D9412G only 1...

Page 43: ...grounded circuit conditions on their sensor loops They transmit the condition of their loops to the panel A ground on the sensor loop reports as a general system ground fault condition see Ground Fau...

Page 44: ...r Outputs to be sure to provide enough power for the OctoPOPITs and other powered devices that will be connected to the system 8 4 2 Listing The D8128D OctoPOPIT Module is UL listed for Local or Polic...

Page 45: ...ules to the D9412G D7412G Both OctoPOPIT and POPEX Modules can be connected to the same Point Bus terminals The modules wire in parallel Remember never assign the same point number to more than one po...

Page 46: ...PIT two OctoPOPIT sensor loops or two POPITs do not function properly 8 4 7 Address Assignment Switches Switches 1 2 3 and 4 assign the OctoPOPIT sensor loops to point numbers on the panel Table 9 sho...

Page 47: ...10 12 13 14 15 16 P1 COMP2 P3 COMP4 P5 COMP6 P7 COMP8 AUX OUT GND IN TO CONTROL 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 P1 COMP2 P3 COMP4 P5 COMP6 P7 COM P8 AUX OUT GND IN TO CONTROL 1 2 3 4 5 6 7 8 9 10...

Page 48: ...lation Guide 43488D Page 48 2002 Radionics D9412G D7412G Off board Points Figure 16b Connecting D8128D OctoPOPITs to the D7412G TO CONTROL 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 P1 COMP2 P3 COMP4 P5 COMP...

Page 49: ...e normally closed and common terminals 9 1 3 Installation Set the switches on the OctoRelay before installing it in the enclosure See section 9 1 1 Configuring the D8129 OctoRelay Install the OctoRela...

Page 50: ...N F P A Sty le 3 5 Si gna l ing Li ne Circuits 32 31 30 29 28 27 PROG CONN Point 8 G ND FA ULT D e te c t E N A B L E D I S A B L E ZONEX OUT2 26 25 ZONEX IN2 ZONEX POWE R 24 ZONEX COMM ON 23 21 22 On...

Page 51: ...pen and common terminals When the output is not activated there is continuity between the normally closed and common terminals Relay outputs may activate while programming the panel You may wish to di...

Page 52: ...R 53 EARTH GRO COMMON BATTERY N Maximum Charging Current 1 4 Amps BATTERY POSITIVE ONLY RELAY A RELAY B RELAY C AUX PO 1 2 3 4 5 6 7 8 9 10 CLASS 2 TRANS 16 5 VAC 40 VAC Part No D1640 Internally Fuse...

Page 53: ...enter with functional keys optimized for local fire alarm control The D1257 is a text display command center for fire annunciation The D1260 boasts an easy to read 4 line by 20 character LCD display w...

Page 54: ...igure 19 shows the D8132 powering command centers in a stand alone configuration For UL certificated accounts use a UL listed power supply The D8132 is not UL listed as a stand alone power supply Cont...

Page 55: ...10 4 4 Keyswitch Operation Maintained Contact If the point to which the keyswitch is connected is programmed for a maintained contact an open on the arming circuit arms the area All faulted points ar...

Page 56: ...D9412G D7412G Operation Installation Guide 43488D Page 56 2002 Radionics D9412G D7412G Arming Devices Notes...

Page 57: ...equires a separate D9131A Parallel Printer Interface Module The D9131A connects to the printer using a standard parallel printer cable 11 3 1 Switch Settings Switches on the D9131A assign a unique add...

Page 58: ...mation software A D9133 Serial Interface Module is required for this application 11 5 1 D9133 Serial Interface Module The Radionics D9133 Serial Interface Module is a four wire powered SDI device prov...

Page 59: ...the Locked or Unlocked position Note Locking the Reset Pin when programming the panel improves upload download time 11 6 1 2 Used as an External Modem The D9133DC can also be used as an external modem...

Page 60: ...D9412G D7412G Operation Installation Guide 43488D Page 60 2002 Radionics D9412G D7412G SDI Devices Notes...

Page 61: ...e programmer is disconnected The prompt in Routing must be programmed YES for this report to be sent 12 2 Accessory Connector Use the Accessory Connector to connect the panel to the D928 Dual Phone Li...

Page 62: ...D9412G D7412G Operation Installation Guide 43488D Page 62 2002 Radionics D9412G D7412G Programmer and Accessory Connections Notes...

Page 63: ...D9412G D7412G Operation Installation Guide 2002 Radionics Page 63 43488D D9412G D7412G FACEPLATES 13 0 Faceplates 13 1 D9412G Faceplate Figure 23a D9412G Faceplate...

Page 64: ...D9412G D7412G Operation Installation Guide 43488D Page 64 2002 Radionics D9412G D7412G 13 2 D7412G Faceplate FACEPLATES Figure 23b D7412G Faceplate...

Page 65: ...allation Guide 2002 Radionics Page 65 43488D D9412G D7412G Appendix A System Wiring Diagrams Issue A Figure 24a D9412G System Wiring Diagram 1 of 3 Appendix A System Wiring Diagrams Issue A A 1 D9412G...

Page 66: ...D7412G Operation Installation Guide 43488D Page 66 2002 Radionics D9412G D7412G Appendix A System Wiring Diagrams Issue A A 2 D9412G Control Communicator 2 of 3 Figure 24b D9412G System Wiring Diagram...

Page 67: ...D7412G Operation Installation Guide 2002 Radionics Page 67 43488D D9412G D7412G Appendix A System Wiring Diagrams Issue A Figure 24c D9412G System Wiring Diagram 3 of 3 A 3 D9412G Control Communicator...

Page 68: ...D7412G Operation Installation Guide 43488D Page 68 2002 Radionics D9412G D7412G Appendix A System Wiring Diagrams Issue A Figure 25a D7412G System Wiring Diagram 1 of 3 A 4 D7412G Control Communicator...

Page 69: ...D7412G Operation Installation Guide 2002 Radionics Page 69 43488D D9412G D7412G Appendix A System Wiring Diagrams Issue A Figure 25b D7412G System Wiring Diagram 2 of 3 A 5 D7412G Control Communicator...

Page 70: ...D7412G Operation Installation Guide 43488D Page 70 2002 Radionics D9412G D7412G Appendix A System Wiring Diagrams Issue A Figure 25c D7412G System Wiring Diagram 3 of 3 A 6 D7412G Control Communicator...

Page 71: ...1 3 6 016 0 1 2 3 056 0 2 096 1 3 017 0 1 2 4 5 6 057 0 3 4 5 6 097 1 4 5 6 018 0 1 2 4 5 058 0 3 4 5 098 1 4 5 019 0 1 2 4 6 059 0 3 4 6 099 1 4 6 020 0 1 2 4 060 0 3 4 100 1 4 021 0 1 2 5 6 061 0 3...

Page 72: ...1 2 4 6 179 0 3 4 6 219 1 4 6 140 0 1 2 4 180 0 3 4 220 1 4 141 0 1 2 5 6 181 0 3 5 6 221 1 5 6 142 0 1 2 5 182 0 3 5 222 1 5 143 0 1 2 6 183 0 3 6 223 1 6 144 0 1 2 184 0 3 224 1 145 0 1 3 4 5 6 185...

Page 73: ...cting to the D9412G 40 Installing 42 D8125 POPIT Modules 39 D8127 POPIT Modules 39 D8128D OctoPOPIT 44 Connecting to the D7412G 48 Connecting to the D9412G 47 D8129 OctoRelay 49 D9127 POPIT Modules 39...

Page 74: ...s Terminals 29 Switched Auxiliary 29 Total Available Power 29 ZONEX 29 Power Supply 25 Primary Power Terminals 25 Printer 57 Programmer 24 Connecting 61 Programmer Connector 61 Programming Standard Fe...

Page 75: ...D9412G D7412G Operation Installation Guide 2002 Radionics Page 75 43488D D9412G D7412G Operation Installation Guide Notes...

Page 76: ...2002 Radionics a division of Detection Systems Inc 43488D 08 02 PO Box 80012 Salinas CA 93912 0012 USA Operation D9412G D7412G Customer Service 800 538 5807 Installation Guide Page 76 of 76...

Reviews: