D9024/D10024
Networking Guide
Page 10 of 18
Peer to Peer [TRUE] ?
Figure 22: Network Menu Six
If necessary, use the
CHANGE
Key to set Peer to Peer to [True] and press
YES
.
The panel displays Network Menu Seven.
Port B Protocol = 0 ? (Normal = 0)
Figure 23: Network Menu Seven
The Port B Protocol for the slave panels in a shared zone network must be set to 0.
Press
YES
.
The panel displays Network Menu Eight.
System events [GLOBAL] ?
Figure 24: Network Menu Eight
Press
YES
.
The panel displays Commission Menu Three.
1)Day Modes 2)Setup options 3)Network [1]
Figure 25: Commission Menu Three
Press
NO
to return to the Configure Menu.
1)CONFIGURE YES)More Options [1]
2)INSPECT
3)NORMAL OPERATION
Figure 26: Configure Menu
Enter 3)NORMAL OPERATION.
The display shows the Memory Check Message.
Don't forget to lock the memory!
2)INSPECT
3)NORMAL OPERATION
Figure 27: Memory Check Message
If the Master Panel and the slave CPU(s) are set up as outlined in section B.2 press 3)Normal
Operation a second time to return to Commission Menu One. Press
RESET.
This closes
the Network process for CPU1 and returns the display returns to Commission Menu Three for the
Master Panel.
4)Talk to Slave
1)Day Modes 2)Setup options 3)Network [10]
Figure 28: Commission Menu Three
Repeat the network programming procedure (beginning at Section B.2.b.) for each slave panel.
After completing network programming for the last slave panel press
NO
from Commission
Menu Three and return to Commission Menu Three for the Master Panel.
Press NO to return to the Configure menu.
Press 3)NORMAL OPERATION to return to the Operator’s Menu, Mail Level.