Radionics D223 Installation Instructions Download Page 3

D223 Installation Instructions

Page 3

©   1996 Radionics

 74-07490-000-B  1/96

WIRE

OPENING

CLEAR

*

A

B

C

0

8

2

5

9

3

6

7

1

4

DISPLAY

ADJUSTMENT

POTENTIOMETER

DATA WIRE

CONNECTOR

(J1)

ON

S1

1

2

3

Figure  3: Inside the D223

The panel’s program affects the keypad’s address:
Choose the keypad address in the panel’s program.
Select Text Keypad for the device type of the chosen
address. For more information, see 

Address Configura-

tion in the D2212 Program Entry Guide  (74-07386-
000).

If a D223 at address 1 is to  be replaced, and the
system has custom text, you must do the following in
order to preserve the custom text:

1. Using a D5200, copy the panel’s program.

2. Attach a new D223 at address 1.

3. Reprogram the panel using the copied program.

Keypad Sounder Disable - To disable the sounder,
turn DIP Switch #3 OFF (see Figure 3).

Fire Points need the trouble sounder: Disabling the
sounder with switch #3 stops the D223 from annunciat-
ing fire point trouble. If fire points are installed as part
of this system, contact the local AHJ to verify code
requirements for fire trouble sounders before disabling
the D223 sounder.

Enable sounder for UL systems: For UL installations,
the sounder on at least one keypad in the system must
remain connected.

Adjust the D223 Display - With the D223 mounted to
the desired surface, view the display from the approxi-
mate angle for the user. If the display requires adjust-
ment for clarity, use the Display Adjustment Potentiom-
eter (R50) in the lower right-hand corner of the D223
circuit board.

Replace the Front Cover - Align the top two tabs of
the enclosure cover with the top two tab slots in the
enclosure base. Slide the top of the cover into the
base.  Gently push the bottom of the cover down on the
base until it snaps into place.

Adjust the Keys - Push each key on the keypad
towards the top of the enclosure to ensure proper
mating with the openings in the top cover.

Summary of Contents for D223

Page 1: ...t mount the keypad in a location exposed to direct sunlight Direct sunlight makes the display less visible and may also damage the keypad components Description The D223 Keypad is a low profile surface mount three wire unit for use with the Radionics D2212 Control Communicator The D223 features an illumi nated keypad a backlit two line LCD text display an armed status indicator three programmable ...

Page 2: ...e wall or gang box place the enclosure base on the wall in the desired location Use a center punch or a pencil to mark the locations of the mounting holes You can mount the enclosure base to a recessed single gang wall box if desired Secure the enclosure base to the wall or gang box Connect the Keypad Wire to the Panel The maxi mum length for all wires connected to D2212 terminal 8 combined is 500...

Page 3: ...ounder Disabling the sounder with switch 3 stops the D223 from annunciat ing fire point trouble If fire points are installed as part of this system contact the local AHJ to verify code requirements for fire trouble sounders before disabling the D223 sounder Enable sounder for UL systems For UL installations the sounder on at least one keypad in the system must remain connected Adjust the D223 Disp...

Page 4: ...wer supply Current Requirements Maximum 140mA Normal 85mA LCD on Standby 30mA No keypad backlighting Enclosure Dimensions Height 4 56 Length 8 15 Depth 816 Color Off white Operating Temperature 0 to 50 C 32 to 122 F Non condensing Relative Humidity 5 to 85 at 30 C 86 F Keypad Wiring Three wire cable supplies data in common and positive voltage Display ON Indicator Lights when system is All or Part...