You can mount the D223 on a flat wall, or on the
following Radionics accessories:

D54B Brass Flush Mount Kit

D54C Chrome Flush Mount Kit

D55 Command Center Desk Stand

D56 Command Center Conduit Box

Route Keypad Wire - Route the wire to the keypad
location. See the panel’s installation manual for
information about the maximum length of keypad
cables and wire resistance.  Route data wire runs
away from electrical, telephone, and other data wiring.

Splice Connectors to the Wires - The three-wire
cable connects to the panel. Use solder to splice the
connectors to the wires. Be sure to insulate all ex-
posed splices with tape so that they do not short to
one another.

Remove the Front Cover - Remove the front cover
from the enclosure base.  Use a small flat-bladed
screwdriver to gently push the two bottom cover tabs
back.  As you push back the tabs, lift the bottom of the
cover away from the base, then remove the cover.

Connect the Keypad - Plug the data wire into the
serial data wiring connector (J1) in the keypad. (see
Figure 3)

Mount the Enclosure Base While pushing any
excess keypad wire back into the wall or gang box,
place the enclosure base on the wall in the desired
location.  Use a center punch or a pencil to mark the
locations of the mounting holes.

You can mount the enclosure base to a recessed
single-gang wall box if desired. Secure the enclosure
base to the wall or gang box.

Connect the Keypad Wire to the Panel - The maxi-
mum length for all wires connected to D2212 terminal
8 combined is 500 feet.  Route data wire runs away
from electrical, telephone, and other data wiring.

Figure 2 shows a typical installation using one D223
Keypad.  Use parallel connections for additional
keypads. For more information refer to the 

D2212

Installation Manual (74-07361-000).

Assigning the D223 to a Device Address - Before
you begin, be sure that the panel’s standby pin is
locked down to prevent missing point reports being
sent.To set the D223 keypad’s address, follow these
steps:

1. Turn DIP switch #1 to the ON position.

2. The display shows:

SET ADDRESS MODE
ADDRESS IS ##

3. Enter the address (1 to 8) with a leading zero

(for example, 01 for address 1).

Important! Use only address numbers 1 to 8.

4. Set dip switch #1 back to the OFF position.

If you are going to use a D223 keypad, at least
one D223 must be set to address 1.

11

12

6

7

8

9

10

5

BLACK

RED

GREEN

RESET

3

2

1

5

6

4

8

9

7

CLEAR

A

B

C

0

*

TEST

CHECK

WATCH

PART ON

ALL ON

ON

ALL ON
SYSTEM OK

Figure  2:  Wiring the D223 to the D2212

Summary of Contents for D223

Page 1: ...t mount the keypad in a location exposed to direct sunlight Direct sunlight makes the display less visible and may also damage the keypad components Description The D223 Keypad is a low profile surface mount three wire unit for use with the Radionics D2212 Control Communicator The D223 features an illumi nated keypad a backlit two line LCD text display an armed status indicator three programmable ...

Page 2: ...e wall or gang box place the enclosure base on the wall in the desired location Use a center punch or a pencil to mark the locations of the mounting holes You can mount the enclosure base to a recessed single gang wall box if desired Secure the enclosure base to the wall or gang box Connect the Keypad Wire to the Panel The maxi mum length for all wires connected to D2212 terminal 8 combined is 500...

Page 3: ...ounder Disabling the sounder with switch 3 stops the D223 from annunciat ing fire point trouble If fire points are installed as part of this system contact the local AHJ to verify code requirements for fire trouble sounders before disabling the D223 sounder Enable sounder for UL systems For UL installations the sounder on at least one keypad in the system must remain connected Adjust the D223 Disp...

Page 4: ...wer supply Current Requirements Maximum 140mA Normal 85mA LCD on Standby 30mA No keypad backlighting Enclosure Dimensions Height 4 56 Length 8 15 Depth 816 Color Off white Operating Temperature 0 to 50 C 32 to 122 F Non condensing Relative Humidity 5 to 85 at 30 C 86 F Keypad Wiring Three wire cable supplies data in common and positive voltage Display ON Indicator Lights when system is All or Part...