D206 Keypad Specifications

Operating Voltage:

Nominal 12 VDC supplied by the control/communicator
auxiliary power supply.

Current Requirements:

Maximum: 140mA

Normal: 85mA

LCD on.

Standby: 30mA

No keypad backlighting.

Enclosure Dimensions:

Height 5.0",   Length 4.5",   Depth .94"

Color: Off white, White

Operating Temperature:

0 to 50 °C  (32 to 122 °F)

Non-condensing Relative Humidity:

5 to 85% at 30 °C (86 °F)

Keypad Wiring:

Three-wire cable supplies data-in, common, and
positive voltage.

Display:

ON Indicator:  Lights when system is All or Part On.

LCD Display:  Two-line 16-character, Liquid Crystal
Display (LCD). The user can select to have the display
backlit constantly, or when a keypad digit is pressed.

© 1996 Radionics, Inc., Salinas, CA, U.S.A. All rights reserved.

™ The Radionics logo is a registered trademark of Radionics, Inc., Salinas, CA, U.S.A.

31946B   9/96

Radionics,  1800 Abbott Street Salinas, CA, 93901, Customer Service: (800) 538-5807

D206 Switch Settings

  Switch #

ON

OFF

1

Set Address

Normal Operation

2

_

_

3

Enable Sounder

Disable Sounder

Summary of Contents for D206

Page 1: ...vent by priority for example the D206 displays alarms before point faults The LCD display is normally illuminated constantly You can choose to make it illuminate only after a key is pressed With this option the display and backlights extinguish after approximately 20 seconds Press and hold the CLEAR key for five seconds to toggle this feature If you re turning the display off hold the CLEAR key un...

Page 2: ...the wall or gang box Connect the Keypad Wire to the Panel The maxi mum length for all wires connected to D2212 terminal 8 combined is 500 feet Route data wire runs away from electrical telephone and other data wiring Figure 2 shows a typical installation using one D206 Keypad Use parallel connections for additional keypads For more information refer to the D2212 Installation Manual 74 07361 000 As...

Page 3: ...e installed as part of this system contact the local AHJ to verify code requirements for fire trouble sounders before disabling the D206 sounder Enable sounder for UL systems For UL installations the sounder on at least one keypad in the system must remain connected Adjust the D206 Display With the D206 mounted to the desired surface view the display from the approxi mate angle for the user If the...

Page 4: ...ree wire cable supplies data in common and positive voltage Display ON Indicator Lights when system is All or Part On LCD Display Two line 16 character Liquid Crystal Display LCD The user can select to have the display backlit constantly or when a keypad digit is pressed 1996 Radionics Inc Salinas CA U S A All rights reserved The Radionics logo is a registered trademark of Radionics Inc Salinas CA...

Reviews: