Route Keypad Wire - Route the wire to the keypad
location. See the panel’s installation manual for
information about the maximum length of keypad
cables and wire resistance.  Route data wire runs
away from electrical, telephone, and other data wiring.

Splice Connectors to the Wires - The three-wire
cable connects to the panel. Use solder to splice the
connector to the wires. Be sure to insulate all exposed
splices with tape so that they do not short to one
another.

Remove the Front Cover - Remove the front cover
from the enclosure base. Insert a small, flat-bladed
screwdriver into the tab on the bottom of the control
center and gently separate the cover from the base.

Connect the Keypad - Plug the data wire into the
serial data wiring connector (J1) in the keypad. (see
Figure 3)

Mount the Enclosure Base While pushing any
excess keypad wire back into the wall or gang box,
place the enclosure base on the wall in the desired
location.  Use a center punch or a pencil to mark the
locations of the mounting holes.

You can mount the enclosure base to a recessed
single-gang wall box if desired. Secure the enclosure
base to the wall or gang box.

Connect the Keypad Wire to the Panel - The maxi-
mum length for all wires connected to D2212 terminal
8 combined is 500 feet.  Route data wire runs away
from electrical, telephone, and other data wiring.

Figure 2 shows a typical installation using one D206
Keypad.  Use parallel connections for additional
keypads. For more information refer to the 

D2212

Installation Manual (74-07361-000).

Assigning the D206 to a Device Address - Before
you begin, be sure that the panel’s standby pin is
locked down to prevent missing point reports being
sent.To set the D206 keypad’s address, follow these
steps:

1. Turn DIP switch #1 to the ON position.

2. The display shows:

SET ADDRESS MODE
ADDRESS IS ##

3. Enter the address (1 to 8) with a leading zero

(for example, 01 for address 1).

Important! Use only address numbers 1 to 8.

4. Set dip switch #1 back to the OFF position.

If you are going to use a D206 keypad, at least
one D206 must be set to address 1.

The panel’s program affects the keypad’s address:
Choose the keypad address in the panel’s program.
Select Text Keypad for the device type of the chosen
address. For more information, see 

Address Configu-

ration in the D2212 Program Entry Guide  (74-07386-
000).

Figure  2:  Wiring the D206 to the D2212

11

12

6

7

8

9

10

5

Black

(Common)

Red

(+12 VDC)

Green

(Data)

PART ON

1

2

3

CLEAR

4

5

6

7

8

9

0

#

A

B

C

RESET

ALL ON

TEST

CHECK

ALL ON

ON

TEST SYSTEM

WEEKLY

Summary of Contents for D206

Page 1: ...vent by priority for example the D206 displays alarms before point faults The LCD display is normally illuminated constantly You can choose to make it illuminate only after a key is pressed With this option the display and backlights extinguish after approximately 20 seconds Press and hold the CLEAR key for five seconds to toggle this feature If you re turning the display off hold the CLEAR key un...

Page 2: ...the wall or gang box Connect the Keypad Wire to the Panel The maxi mum length for all wires connected to D2212 terminal 8 combined is 500 feet Route data wire runs away from electrical telephone and other data wiring Figure 2 shows a typical installation using one D206 Keypad Use parallel connections for additional keypads For more information refer to the D2212 Installation Manual 74 07361 000 As...

Page 3: ...e installed as part of this system contact the local AHJ to verify code requirements for fire trouble sounders before disabling the D206 sounder Enable sounder for UL systems For UL installations the sounder on at least one keypad in the system must remain connected Adjust the D206 Display With the D206 mounted to the desired surface view the display from the approxi mate angle for the user If the...

Page 4: ...ree wire cable supplies data in common and positive voltage Display ON Indicator Lights when system is All or Part On LCD Display Two line 16 character Liquid Crystal Display LCD The user can select to have the display backlit constantly or when a keypad digit is pressed 1996 Radionics Inc Salinas CA U S A All rights reserved The Radionics logo is a registered trademark of Radionics Inc Salinas CA...