![Radionics D206 Installation Instructions Download Page 2](http://html.mh-extra.com/html/radionics/d206/d206_installation-instructions_780446002.webp)
D206 Installation Instructions
Page 2
31946B 9/96
© 1996 Radionics
Route Keypad Wire - Route the wire to the keypad
location. See the panel’s installation manual for
information about the maximum length of keypad
cables and wire resistance. Route data wire runs
away from electrical, telephone, and other data wiring.
Splice Connectors to the Wires - The three-wire
cable connects to the panel. Use solder to splice the
connector to the wires. Be sure to insulate all exposed
splices with tape so that they do not short to one
another.
Remove the Front Cover - Remove the front cover
from the enclosure base. Insert a small, flat-bladed
screwdriver into the tab on the bottom of the control
center and gently separate the cover from the base.
Connect the Keypad - Plug the data wire into the
serial data wiring connector (J1) in the keypad. (see
Figure 3)
Mount the Enclosure Base - While pushing any
excess keypad wire back into the wall or gang box,
place the enclosure base on the wall in the desired
location. Use a center punch or a pencil to mark the
locations of the mounting holes.
You can mount the enclosure base to a recessed
single-gang wall box if desired. Secure the enclosure
base to the wall or gang box.
Connect the Keypad Wire to the Panel - The maxi-
mum length for all wires connected to D2212 terminal
8 combined is 500 feet. Route data wire runs away
from electrical, telephone, and other data wiring.
Figure 2 shows a typical installation using one D206
Keypad. Use parallel connections for additional
keypads. For more information refer to the
D2212
Installation Manual (74-07361-000).
Assigning the D206 to a Device Address - Before
you begin, be sure that the panel’s standby pin is
locked down to prevent missing point reports being
sent.To set the D206 keypad’s address, follow these
steps:
1. Turn DIP switch #1 to the ON position.
2. The display shows:
SET ADDRESS MODE
ADDRESS IS ##
3. Enter the address (1 to 8) with a leading zero
(for example, 01 for address 1).
Important! Use only address numbers 1 to 8.
4. Set dip switch #1 back to the OFF position.
If you are going to use a D206 keypad, at least
one D206 must be set to address 1.
The panel’s program affects the keypad’s address:
Choose the keypad address in the panel’s program.
Select Text Keypad for the device type of the chosen
address. For more information, see
Address Configu-
ration in the D2212 Program Entry Guide (74-07386-
000).
Figure 2: Wiring the D206 to the D2212
11
12
6
7
8
9
10
5
Black
(Common)
Red
(+12 VDC)
Green
(Data)
PART ON
1
2
3
CLEAR
4
5
6
7
8
9
0
#
A
B
C
RESET
ALL ON
TEST
CHECK
ALL ON
ON
TEST SYSTEM
WEEKLY