1. Every time when a battery cell is fully charged, the charger will give four beeps, and the voltage
value of the battery cell will show a green background.
2. During the charging process, if the battery is in poor contact, there will be beep warning tone.
Please unplug the battery and then replug it.
4.2 DISCHARGE
The discharging current of CB86-PLUS charger is fixed at 1.2A. And the discharging voltage can be
set. Start the DISCHARGE mode, the charger will discharge the battery to the voltage you set. Make
sure to set an appropriate discharging voltage, because over-low discharging voltage will cause over-
discharging, which will damage the battery and shorten its life span. If the discharging voltage
exceeds the battery's voltage, it will not be able to discharge. Because of the heat generated during
discharge, the charger's cooling fan will work automatically. When the charger discharges the battery
to the level equal to the set discharging voltage, the discharging is completed.
If the battery will not be used for a long time, it is recommended to discharge the battery to 3.8V
before storing. If the voltage of the battery is too high, long-term storage may damage the battery.
Setting method: The setting method of discharging voltage is the same as that of charging voltage,
please refer to Page 14,
charging voltage setting method
.