background image

RD7100 QUICK START GUIDE 

Active Locating – Receiver Operation

 

 

 Turn on receiver by pushing            button. 
 

 

 Set frequency to 33khz Line Mode, using            button. 
 

 

 Set antenna to peak          mode using              button. 

 
 
 
 

Receiver indicates position of underground conductor by showing 
highest bar graph and signal strength percentage with the compass 
in straight up and down position as shown. 

SCAN

 for strongest signal. 

 
 

• Circle around transmitter to detect strongest signal. 
 

 

 

• Adjust gain using          buttons. 

 

 

For best response bar graph should reach maximum signal 
at approximately 60%.

 

PINPOINT

 exact location of conductor. 

 

 Bar graph will rise and fall as blade is  

moved across conductor. 

 

 Memory bar on graph shows strongest signal response. 

 

 Once strongest signal is located . . .  

Rotate receiver as shown. Bar graph will reach maximum 
signal when receiver is properly aligned over conductor and 
the compass is in the straight up and down position. 

Depth is displayed on screen automatically when receiver is properly 
aligned over conductor.

 

TRACE

 the path of conductor. 

 

 Bar graph will rise and fall as blade is moved across 

conductor. 
• The compass shows the direction of the target conductor 
relative to the receiver.  Keeping the compass straight up and 
down insures the receiver is aligned properly over the 
conductor. 

 

 Adjust gain using up & down arrows to have bar graph reach 

maximum signal at approx. 60%. 

 

Repeat 

PINPOINT

 & 

TRACE

 steps along path of conductor.

 

Bar Graph & Signal Strength % 

Frequency 

Peak Antenna  Depth 

Gain 
Level 

Line Indicator 

Compass 