6
7
RD5100H
2
OTx transmitter
Your safety or the safety of others may be at risk if the RD5100H
2
OTx is not used in
accordance with the manufacturers’ instructions.
Key to symbols used on the RD5100H
2
OTx Transmitter:
6
7
2
4
1
5
3
Transmitter front panel
1. On/Off key.
2. On/Off red LED.
3. Alkaline battery warning red LED: Flashes when batteries are in use and are low.
4. Lithium Ion rechargeable battery warning red LED: Flashes when batteries are in
use and are low.
5. Accessory socket for direct connection lead, signal clamp and charging internal
Lithium Ion rechargeable battery pack.
Transmitter rear panel
6. Fuse holder.
Note: The transmitter is supplied with a non-fitted fuse for shipping and before
use this will have to be inserted into the fuse holder.
7. Alkaline battery compartment: Requires 4 D-Cells (LR-20).
The RD5100H
2
OTx transmitter incorporates a rechargeable Lithium Ion battery pack
and this is the intended primary power source for the transmitter. When the Lithium Ion
low battery level LED illuminates the user should either recharge the battery pack using
the Radiodetection supplied charger or alternatively fit 4 alkaline batteries. If alkaline
batteries are fitted to the transmitter, these will be detected automatically and the
transmitter will take its power from the alkaline batteries. When the alkaline batteries are
low, the alkaline low battery level LED will illuminate.
SYMBOL
DESCRIPTION
Refer to manual for specific safety instructions or advice.
Accessory connection socket.
Type and orientation of auxiliary battery:
Standard D Cell (LR20), max 1.6V voltage per cell.
For best performance use alkaline batteries.
RD5100H
2
OTx Transmitter Technical Specification:
Frequency
83kHz (83,077Hz ±5Hz).
Nominal power output
1W in Direct Connect mode.
Batteries
Internal rechargeable battery, 4 x D-Cells (LR-20).
Warranty
12 months.
36 months.
†
Compliance
FCC, RoHS, WEEE, CE.
Weight
1.6kg (3.5lbs) (including rechargeable batteries).
Environment
IP54.
Operating temperature range
-20°C to +50°C (-4°F to 122°F).
Storage temperature range
-40°C to +70°C (-40°F to 158°F).
Output voltage
Max 30V RMS (Direct Connect Mode).
†
Extended warranty available upon registration, within 3 months of purchase, at:
https://portal.radiodetection.com/