The power output levels are:
Direct connection
Induction
One LED lit
5 mA
25%
Two LEDs lit
10 mA
50%
Three LEDs lit
30 mA
75%
Four LEDs lit
100 mA*
100%
* Limiting current reduced to 60mA for frequencies less than 1kHz. At 45kHz and above the output power is
limited to 1W to comply with current legislation
The sounder tone indicates connection quality. A lower tone indicates a better connection (more output on the
line)
FF mode (RD4000T3F only)
Press the frequency key to select FaultFind. The red FF LED and all four output power LED’s will illuminate.
Note: In FF mode, it is not possible to alter the output power level.
RD4000T10 OPERATION
Switching the transmitter on/off
Press the on/off key once to switch the transmitter on. Press the key again to enter the menu mode.
To switch the unit off, press the on/off button until the LCD display clears.
Checking battery level
The battery level indicator is situated at the top right hand side of the display and is made up of four segments.
As the remaining battery life reduces the segments change colour from black to clear to indicate the amount of
battery life left. When there is one black segment left the 'Almost Discharged' indication will flash and the battery
discharge alarm will sound until the battery is discharged.
Note: Ensure that you always have enough batteries available to complete the task.
Selecting a frequency in locate mode
The frequencies are those chosen by the customer at the time of transmitter purchase. If the values of the
frequencies require changing when the unit is in-service, the unit can be re-configured by using the web-
enabling feature (does not apply to induction frequencies).
•
Switch on the unit
•
Press the frequency key to scroll through the available frequencies. The selected frequency is displayed.