The VOP and characteristic impedance values for some common cable types are:
Use/Type
Cable type
VoP
Ethernet
0.77
RG58
0.78
RG58/U
0.76
Thicknet
0.77
Thinnet
0.68
Twisted pair
0.66
U/UTP cat 5e, 6
0.67
UTP26
0.64
Gel 0.912
0.68
Gel 0.643
0.65
Gel 0.511
0.64
Gel 0.404
0.63
Paper 0.643
0.69
Paper 0.511
0.68
Paper 0.404
0.68
PE 0.912
0.69
PE 0.643
0.68
PE 0.511
0.66
PE 0.404
0.65
PTFE
0.71
Air
0.96
Paper
0.70-0.88
Paper Oil Filled (PILC)
0.50-0.56
Paraffin
0.64
PE
0.67
PTFE
0.71
PE foam
0.82
XLPE
0.52-0.58
Data
Phone
Power