PTT and then change the value of each option with the UP or DOWN keys.

5. T-CTC

Enter this option following previous menu operating mode. The C-CTC is to change the setting options OFF, 67.0, D023N, D0231 by pressing PTT

and then change the value of each option with [UP] or [DOWN].

6. TX-POWER

Enter this option following previous menu operating mode. TX-POWER has two options: HIGH (high power) and LOW (low power). You can use the

[UP] or [DOWN] key to select. When the communication distance allows, use the low power (LOW) as much as possible to extend the battery life.

7. CH-BAND

Enter this option following previous menu operating mode. The CH-BAND has wideband WIDE and narrowband NARROW; when it is set to WIDE,

it means that it is in broadband working state; when it is set to NARROW, it means that it is in narrowband working state.

8. SAVE

Enter this option following previous menu operating mode. The power save switch (SAVE) range is ON and OFF. You can use the [UP] or [DOWN]

key to select. When you select the power saving function ON, the standby time of your machine is longer, which means that you will use the machine

for a long time after it has been fully charged. When you select the power saving function OFF, the use time will be shortened each time the battery is

charged, but the real-time communication effect will be better.

9. BEEP

Enter this option following previous menu operating mode. The beep switch setting (BEEP) range is ON and OFF. You can select with the [UP] or

[DOWN] key. When you select OFF, it means that this function is off. There will be no beep for any operation of this machine. When you select ON,

it means that this function is on. Any operation of this machine will beep.

10. STEP

Enter this option following previous menu operating mode. The step frequency selection function (STEP) range is 5 kHz, 6.25 kHz, 10 kHz, 125 kHz,

and 25 kHz, which you can select with the [UP] or [DOWN] key.

11. STOR-CH

First, in the VFO mode, select the frequency and sub-audio parameters and then enter this option according to previous menu operating mode, select

the channel number to be stored by [UP] or [DOWN] key, select the channel number and use [ FUN] key to confirm storage.

12. DEL-CH

Enter this option following previous menu operating mode. Use the [UP] or [DOWN] key to select the channel number you want to delete. Select the

channel number and confirm with [FUN].

Summary of Contents for iRaddy GM Series

Page 1: ...iRaddy GM 4 5 6 User Manual ...

Page 2: ...s PPT key For transmitting signals Power button For on off USB port For charging the battery serving as power bank to charge the phone reading and writing talkback frequency information LCD screen For displaying the working status of the current machine Function button For operating various settings of the machine Microphone For inputting sound signals ...

Page 3: ...mobile phone when the machine is out of power use USB cable to connect 5V to the USB port of the unit to charge the battery Basic operation Power on off Press and hold the key until you hear the didu sound and the screen lights up indicating that the power of the interphone is turned on in the power on state press and hold the key until you hear the didu sound and the screen goes out indicating th...

Page 4: ...ous menu operating mode The VOLUME range is 0 15 the smaller the value is the smaller the speaker output volume is In addition you can adjust the volume by pressing and holding the UP DOWN buttons 2 SQLNUM Enter this option following previous menu operating mode The SQLNUM range is 0 9 You can use UP or DOWN key to select The lower the SQL value is set the stronger the ability to receive weak sign...

Page 5: ...means that you will use the machine for a long time after it has been fully charged When you select the power saving function OFF the use time will be shortened each time the battery is charged but the real time communication effect will be better 9 BEEP Enter this option following previous menu operating mode The beep switch setting BEEP range is ON and OFF You can select with the UP or DOWN key ...

Page 6: ...ng the desired frequency press the FUN button again to confirm the exit Press the V M key to cancel the exit during setup Troubleshooting guide Problems Solutions No sound and reaction The battery pack may be exhausted Replace it with a new one or recharge it The battery pack may not be installed correctly Remove the battery pack and reinstall it The battery will not last long after it is fully ch...

Page 7: ...emperature range 20 70 Group frequency Phase locked loop frequency synthesis Memory channel 16 channels Antenna configuration Rubber antenna Antenna resistance 50Ω Working mode same frequency simplex or different frequency simplex Grounding negative electrode Dimensions 145 71 18mm excluding antenna Weight About 200g including antenna Emission part value Receipt part value Output power 0 5 2 W Sen...

Reviews: