RC11xx(HP)-TM
RC25xx(HP)-TM
RC17xx(HP)-TM
2016 Radiocrafts AS
RC11xx(HP)/25xx(HP)/17xx(HP)-TM Data Sheet rev. 1.48 Page 61 of 86
2016 Tiny Mesh AS
Radiocrafts
Embedded Wireless Solutions
Parameter
Description
Addr
ess
Argument
Factory
setting
Comment
FW
Pulse Counter Mode
Enables the pulse
counter function
96
0: Off
1: On,W/ Pull Up
3: On,W/O Pull Up
0
Bit map of selections
Bit 0 (bit val. 1): PC On / Off
Bit 1 (bit val. 2): Pull Up Disable
Bit 2 (bit val. 4): TBA
1.40
Pulse Counter
Debounce
De-bounce time in ms
for Pulse counter
97
0-255
0 = no de-
bounce
1.40
Connection Change
Margin
Minimum difference in
RSSI to justify
automatic change of
network connection
98
0-255
12
Do not Change
1.37
Clustered Node
Device Limit
Minimum number of
densely located nodes
required to be defined
as a cluster
99
5-100
10
Closely located nodes are forced to
act as a single node by reducing
network Beacon (HIAM) activity
1.34
Clustered Node RSSI RSSI level to form a
node cluster
100
40-100
60
1.34
Detect Network Busy
Gateway action when
network activity
detected after Reset.
101
0-3
39
0: Ignore
1: Halt+Warn
2: Warn
0
Applicable in Packet mode only
1.20
RF Jamming Detect
RF Jamming Detection
Time
102
0-100
0 = Off
Minimum time in minutes of
continuous radio jamming
on all radio channels before an RF
Jamming alarm is generated
1.34
RF Jamming Alarm
Port
GPIO port used for RF
Jamming alarm output
103
0-7, 255
0-7:Selected port
255: Disabled
40
255
The selected GPIO will go LOW on
alarm status, and
will remain LOW for as long as
alarm status is present.
Note: Selected GPIO must be
configured for High Output
1.34
Feedback Port
GPIO selection for
Pulse Counter
Feedback
104
0-7, 255
0-7: Selected port
255: Disabled
40
255
Port configuration must be set for
Output
1.40
Feedback Enable
Select event types that
will generate feedback
flash
105
0,2
0: No Feedback
2: Pulse Count
0
1.40
IMA Message Data
Field Contents
Selects contents of
Message Data field in
IMA Message
106
0-6
0 : No data
1: GPIO Trig-hold
2: Pulse Counter
3: Analogue2
41
4: Analogue3
41
5: My Connects
10
6: MyLocatorRSSI
0
1.40
IMA Message
Address Field
Contents
Selects contents of
Address Data field in
IMA Message
107
0-
0: No Data
1: Pulse Counter
2: Locator ID
3: Destination ID
4: Alternate
Destination ID
10
5: An3
41
6: IMA count
41
2
1.40
Trig Hold
Bitmap of triggered
GPIO inputs that will be
reported next IMA
period
108
0-255
0
1: GPIO 0
16: GPIO 4
2: GPIO 1
32: GPIO 5
4: GPIO 2
64: GPIO 6
8: GPIO 3
128:GPIO7
Add values for multiple ports
Example: 7= GPIO 0+1+2
Port must be enabled for event trig
1.40
End Device Awake
Port
Selects GPIO to signal
Awake condition for End
Device
109
0-7, 255
0-7: Selected Port
255: Disabled
255
1.40
Configuration Lock
Override
Enables configuration of
locked parameters
when SID not 0 0 0 1
110
0: Locked
1: Lock Override
0
1.43
Reserved
111-
112
Group Table
Group IDs that this node
belongs to
113-
120
0-255
0,0,0,0,0,0,0,
0
See Page 25 for Group addressing
1.40
38
Out of range values will be treated as 0
39
Value larger than 2 will be treated as 2
40
Out of range values will be treated as Disabled
41