Page
51
of
60
©
2019 Radiocrafts AS
MBUS User Manual (ver 2.01)
MBUS USER MANUAL
Parameter
Addr
(hex)
MBU
S
3
MBU
S
4
Argument
range
Comment
Default/
Factory Setting
SLEEP_MODE
0x04
✔
✔
Sleep mode.
When enabled the module enter Sleep mode after
transmission (or reception). Delay set by
RX_TIMEOUT
If enabled with sleep timeout, the module goes
directly to Sleep after a Reset, and to Sleep after
TIMEOUT when wakeup from Sleep or exit Config
mode.
0
0x00
Disable sleep
1
0x01
Enable sleep after TX
2
0x02
Reserved
3
0x03
Enable sleep after TX and RX
5
0x05
Enable sleep after TX
+ sleep timeout
7
0x07
Enable sleep after TX and RX
+ sleep timeout
0x00
RSSI_MODE
0x05
✔
✔
Append RSSI to received data. When enabled the
RSSI value is appended to the received data
0
0x00
Disabled
1
0x01
Enabled
0x00
PA_TABLE_EXTENDED 0x06
✘
✔
0 Disables. 1-20 is on. See Data Sheet for output
power levels.
0
0x00
Extended table disabled.
RF_POWER apply.
1-20
0x01-0x14
Default power step
0x00
CAT1_ENABLE
0x07
✘
✔
0
0x00
Disabled
1
0x01
Enabled
0x00
Radio Packet configuration
PREAMBLE_LENGTH
0x0A
✔
✔
MBUS3: Short of long preamble in S mode only.
MBUS4: Transmit frame format A or B
MBUS3
S-mode
MBUS3
Other
MBUS4
0
0x00
Short
-
FFA
1
0x01
Long
-
N.A
2
0x02
-
-
FFB
0x00