What wires do you have?

 Make sure your wires are labeled. This may require you to 

find the ‘other end’ connection for each wire on your heating or air conditioning equipment and read 

the label there. Refer to the Wire Reference page at end of install section for better understanding of 

wire labels from different HVAC system makers.

 IMPORTANT: 

 The CT30 runs on 3 AA alkaline batteries and/or the C wire if available. If you do 

not have a C wire you can run a new wire from the HVAC or use a standard 12-24V [AC or DC] wall 

transformer. A constant power source is required when using a radio module.

 IMPORTANT: 

If you have both RH and RC you need to 

remove the jumper wire between these 2 terminals.

Prepare Wires

 

Please follow these guidelines for safe and 
secure wire connections:

• You will need at least 2.6” of wire for each of your connections to the CT30.  

• If you do not have enough wire, splice additional wire to allow enough slack 

• Terminals accept wires from 16-22awg.

• Fan out wires below the hole as shown.

• Remove insulation 1/8” from the tip of each wire.

• Take care not to damage the labels for each wire in handling.

 

G

C

Y

RH

W

2.6"

from HVAC 

System

Jumper 

wire

Wire Termials

Y  RH  RC  G  A 

Summary of Contents for CT30

Page 1: ...s designed for use with 3AA alkaline batteries and or 24 volt AC C wire or a 12 24 AC or DC source and millivolt gas systems Each thermostat relay load should be limited to 1 0 amp higher amperage may...

Page 2: ...there are unusual heating conditions such as in direct sunlight near a lamp radio television radiator register fireplace near hot water pipes in a wall or near a stove on the other side of a wall Do...

Page 3: ...carefully before removing any wiring from existing thermostat Wires must be labeled before they are removed THERE IS NO STANDARD COLOR CODE When remov ing wires from their terminals ignore the color o...

Page 4: ...a standard 12 24V AC or DC wall transformer A constant power source is required when using a radio module IMPORTANT If you have both RH and RC you need to remove the jumper wire between these 2 termin...

Page 5: ...eat Cool From Furnace RC C Y RH W C W Y RH G 4 Wire Heat Cool From Furnace G C Y RH W C W RH G 3 Wire Heat From Furnace C RH G W From Furnace C W C W RH RH 2 Wire Heat From Furnace W RH A W RH A 3 Wir...

Page 6: ...terminal area Do not bunch wires behind the CT30 Feed any slack back into the wall opening Connect Your Wires Connect labeled wires only to a terminal with the same letter label Insert the wire in the...

Page 7: ...e CT30 to the wall with the screws provided 4 If you are mounting the CT30 to sheet rock or if you are using the old mounting holes use the plastic anchors provided 5 Mark first and drill a 3 16 in 4...

Page 8: ...AA Batteries Install 3 AA alkaline batteries required following the marked polarity in the battery compartment Put the lower battery in negative end first against the spring then push the positive end...

Page 9: ...r a month or more you should replace the batteries as a precaution against battery failure in your absence Always use new alkaline batteries Failing to replace the batteries when necessary could cause...

Page 10: ...age HEAT 2 stage COOL select 3 If you want efficient but slower recovery 2 stage HEAT 1 stage COOL select 4 2 stage HEAT 2 stage COOL select 5 NOTE For 2 stage systems your CT30 can recover from a tem...

Page 11: ...screen Touch the icon and raise the target temp to 90 o F allow the system 2 minutes to respond Verify that heat is blowing from the system Return the Target Temp to a nomal setting Return mode to OF...

Page 12: ...heating It cannot be used with line voltage systems This thermostat is digital and your desired heat or cool temperatures can easily be set on the large touch screen with the buttons A minimum 4 minu...

Page 13: ...Heat STEP 1 Connect the R or RH wire to the RH terminal This connects the heat power STEP 2 Connect the W wire to the W terminal This connects the heat STEP 3 Connect the G wire to the G terminal on t...

Page 14: ...RH RC G WIRES 5 Wire Heat Cool STEP 1 Connect the W wire to the W terminal This connects the heat STEP 2 Connect the Y wire to the Y terminal This connects to the cooling compressor STEP 3 Disconnect...

Page 15: ...he O or B wire to the B terminal This connects the change over valve If you have both O and B connect O wire to O terminal WARNING DO NOT connect B to B terminal see wire reference under Trane for B w...

Page 16: ...the G terminal This connects the fan STEP 7 Set HVAC selection switches to NORMAL and If you have gas or oil heat set the HEAT TYPE to GAS If you have electric heat set the HEAT TYPE to ELEC Your HVAC...

Page 17: ...e COOL control or 2nd stage compression for a heat pump G or F G FAN control C or X C 24VAC power to power thermostat NOTE TRANE uses B for this connection H H External Humidifier DH DH External De Hu...

Page 18: ...thermostat W or W1 W2 2nd stage HEAT X2 Emergency heat do not connect tape off Zoned Hot Water 2 wire Your Wires Thermostat Terminal R RH W W 3 Wire Motor Driven Valves R or 5 RH power W or 4 W heat...

Page 19: ...PG 19 Notes on your system...

Reviews: