47
Scanner will not track a
trunked system.
(continued)
The data frequency is
missing.
Find the data frequency
(see “Programming
Trunked Frequencies” on
Page 26).
PROBLEM
POSSIBLE CAUSE
REMEDY
The system you are try-
ing to track is a Type I
system, and the scanner
is set to scan Type II sys-
tems.
Set the scanner to
receive Type I trunked
frequencies. See “Scan-
ning Type I and Hybrid
Trunked Systems” on
Page 33.
Scanner will not stop
while scanning a scan
list.
No IDs have been
stored.
Store one or more IDs
(see “Scan Lists” on
Page 31).
The IDs you have stored
are not active.
Scan another transmis-
sion.
Scanner will not acquire
a data channel.
SQUELCH
is not cor-
rectly adjusted for trunk
tracking.
Adjust squelch for trunk
tracking. See “Setting
Squelch for the Trunk
Tracking Mode” on
Page 26.
The frequency used for
the data channel is miss-
ing.
Add the frequency used
for the data channel to
the frequency list. (see
“Programming Trunked
Frequencies” on
Page 26).
Missing replies to con-
versations.
The system you are try-
ing to track is a Type I
system, and the scanner
is set to scan Type II sys-
tems.
Set the scanner to
receive Type I trunked
frequencies. See “Scan-
ning Type I and Hybrid
Trunked Systems” on
Page 33.
PROBLEM
POSSIBLE CAUSE
REMEDY
20-430.fm Page 47 Wednesday, August 4, 1999 1:29 PM