background image

4.

Touch

the

thermocouples

probe

to

the

object

you

want to test.

Wait until

the

reading

stabilizes.

Note:

+

Apply

coolant

to

the metal head

of

the

thermocouple's probe

to quicken

the

process of temperature detection.

+

When

the

device's

temperature

is

above

140°F (60°C),

remove the thermocouple

once

the

reading stabilizes. The

thermocouple cannot

work

at

high

temperature

for

extended periods

of

time.

Replacing

the

Fuses

If

the

meter

stops

working,

replace

one or both of the fuses.

The spare

250V/500mA sand-filled ceramic

fuse,

and 250V/12A

sand-filed

ceramic

fuse

are

stored

in

the

holders

inside

the cabinet near the top of

the

meter.

1.

Turn

off

the

meter and

disconnect

the

test

leads.

2.

Loosen

the

three screws from

the

back

cover and gently

pull

apart

the

case.

3.

Pullthe red

ribbon

to pop out

the

fuse.

4.

Remove

the

spare fuse from

the

plastic

holder and insert

it into

the

fuse

holder through

the

loop

of

the

attached

ribbon.

Check

the

rating

of

the

fuse

carefully and

choose

the

proper one.

5.

Replace

the

back cover and secure

it

with

the

screws.

F1

Spare Fuse

F2

Spare Fuse

O

Bl

o

=

I)

=

o

3

pabueapy

F1:250V/500mA Sand-

Filled

Ceramic Fuse

(Replace

with

Cooper

Bussmann

S501

series

fuse

only)

F2:250V/12A Sand-

Filled

Ceramic Fuse

(Replace

with

Cooper

Bussmann

ABC

series

fuse)

21

Summary of Contents for 2200087

Page 1: ...ote The supplied USB cable with ferrite must be used with your multimeter to ensure compliance with the Class B FCC limits Section 15 27 Ce We hope you enjoy your True RMS Digital Multimeter from Radi...

Page 2: ...Capacitanc Checking Continuity Checking Diodes Measuring Logic Measuring Frequency Duty Cycle Pulse Width Measuring AC Voltage AC Current Frequency Measuring heg Advanced Operation System Requirement...

Page 3: ...aA 2 inside meter Features Measures voltage current resistance capacitance frequency temperature and more True RMS for more accurate AC voltage and current readings Auto ranging with manual ranging ov...

Page 4: ...You can order replacement leads from your local RadioShack store Donotuseafuse of brand or rating other than those specified here Doing so might damage your meter Because many AC DC sets have a potent...

Page 5: ...ON CATEGORY II 3600VA max 500V To avoid electrical shock or instrument damage do not MAX connect the common input terminal COM jack to any k source that exceeds 500 volts with respect to earth ground...

Page 6: ...or bury them Ifyou do not plan to use the meter fora month or more remove the batteries Batteries can leak chemicals that can destroy electronicparts When Z3 appears or the meter stops operating prop...

Page 7: ...an 400maA plug the red test lead into 10A MAX instead of V mA Q AN WARNING Although the test leads are rated for 1000 volts and the maximum rating of this meteris 1000 volts DC 750 volts RMS AC do not...

Page 8: ...res current Qrit Measures ohms and capacitance o Pk Checks continuity and diodes Hz LOGIC Measures logic HI LO frequency hee Measures the gain of small signal bipolar transistors OFF Switches offthe m...

Page 9: ...Selects auto or manual ranging Selects different ranges in manual range mode RELA Takes relative measurements Hz DUTY WIDTH Measures frequency duty cycle and pulse width MAX MIN Stores maximum and min...

Page 10: ...r off function turn the meter off then back on Select a Function and Range Each position on the function dial accesses one or more individual functions To select a function 1 Turn the function dial to...

Page 11: ...pe OR dddd pA dd dd mA ddd d mA dddd A dddd A ddd dQ d ddd kQ dd dd kQ Set the meter to any function except C F dBm TF LOGIC or hgg Connect the test leads tothe circuit Press RANGE to select a suitab...

Page 12: ...ing To manually set the range press RANGE NUI disappears Press RANGE again to change the range if necessary 3 Power offthe circuit under test Touch the test leads to the circuit Or to measure AC volta...

Page 13: ...selected range Move the red test lead to V mA Q Rotate the function dial to pA A or mA A depending on the value you measured in Step 6 Reapply power to the circuit t 1 Note Ifyou are measuring DC curr...

Page 14: ...ve one of the leads of the capacitor fromits circuit and connect the test leads to the capacitor s matching positive or negative terminals The measured value appears Note The voltages applied across e...

Page 15: ...est leads to the component Note the first reading 5 Reverse the test leads and note the second reading If one reading shows a value and the other is overrange OF appears the device is good If OF appea...

Page 16: ...V peak 1 Rotate the function dial to Hz LOGIC 2 Press SELECT until Hz KHz or MHz appears Otherwise press Hz DUTY WIDTH to select duty cycle function appears or pulse width function uS or mS appears 3...

Page 17: ...pinout 1 2 Ifthe function dial is set to 2V dBm and you want to set the meter for maximum sensitivity when measuring a new signal press SELECT to select the AC V function then press Hz DUTY WIDTH to...

Page 18: ...ware 1 Turn on your computer and start the installed Windows operating system 2 Use the supplied USB cable to connect the multimeter to your computer Note the sticker Connect to PC on the cable 3 Inse...

Page 19: ...ter allows you to take relative measurements for certain functions This allows you to measure very low resistance or identify closely matching measurements This feature is not available for C F dBm 9...

Page 20: ...ve relative value A reading of 0 00 indicates an exact match To stop relative measurement press RELA again or set the function dial to another setting Note Forthe most accurate reading the temperature...

Page 21: ...and filed ceramic fuse are stored in the holders inside the cabinet near the top ofthe meter 1 Turn offthe meter and disconnect thetestleads 2 Loosen the three screws from the back cover and gently pu...

Page 22: ...ng 3 in last digit B00V wooo 0 6 of reading 3 in last digit FEO ersssnsmsmmrey 0 8 of reading 4 in last digit DC CURRENT Maximum measurement 10A 600A 60mA 6A 6mA 400mA JOA creme 0 8 of reading 5 in la...

Page 23: ...n last digit Sensitivity The function dial set to Hz LOGIC 10Hz 4MHz L00HzZ 1KFlz LOKHZ vuaamsnmimmmmmpssssesases rE 50mVrms 100mVrms For DC and AC voltage frequency the function dial set to V dBm max...

Page 24: ...alue coo Overflow 6000 counts Range Down Detect Value 580 counts Low Battery Indication snBAN RO BY Sleep Mode CUMTeNt cero10 pA normal 20pA Max Input Impedance DCV ACV 10 megohmin parallel with 50pF...

Page 25: ...the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to wh...

Page 26: ...e for parts and labor b replace the product with the same or a comparable product or c refund the purchase price All replaced parts and products and products on which a refund is made become the prope...

Page 27: ...ntial damages so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state You may contac...

Page 28: ...istered trademarks of Microsoft Corporation in the United States and or other countries 2013 RadioShack Corporation Allrights reserved RadioShack is a registered Printed trademark used by RadioShack C...

Reviews: