40
Radijator Inženjering DOO, 36000 Kraljevo, Živojina Lazića Solunca br.6, Srbija
tel. +381 36 399 140, fax. +381 36 399 150,
, e-mail: [email protected]
Children must be supervised by a guardian as they do not play with the appliance boiler.
If the damaged power protection, must be replaced in the factory and serviced by an
authorized dealer or qualified people to avoid the risk of electric shock.
1.3. Minimum distance from flammable materials
Provide adequate distance from flammable materials, if necessary, to ensure the
protection of the same.
Minimum distance from flammable materials is required by law - please inquire of
professionals who deal with heating and Emission effluents.
The minimum distance of the boiler and flue pipe gas from the low and averagely
combustible materials should be at least 100 mm.
Minimum distance from flammable materials is 200 mm, and the same goes for
materials whose flammability is not known.
Risk of fire!
Storage of flammable materials and liquids in the vicinity of the boiler is prohibited.
Be sure to warn users about the required minimum distance of combustible material
from the boiler.
Combustibility of Construction materials
A
Asbestos, stone, building stone, ceramic wall tiles,
terracotta, plaster, screed (without organic additives)
Non-combustible
B
Gypsum cardboard slab, glass fibre slab of ACUMINE,
ISOMINE
Non easily flammable
C1
Beech and oak wood, composite wood, file, slab of
HOBREX, Versatile, umakart
Low combustible
C2
Wood of pine, yew and pine, composite materials
Averagely combustible
C3
Asphalt, paperboard, cellulose materials, chipboard,
cork, polyurethane, polystyrene, polypropylene,
polyethylene fibre floor
Easily combustible