Installation Manual
BOILER INSTALLATION
MINIMUM DISTANCES FOR
FIXING TO WALL
MINIMUM DISTANCE mm.
45
0
60
450
60
1200 min.
400
m
m
A
MINIMUM DISTANCE mm.
SECTION A-A
40
0
m
m
A
Balcony
S
S
To allow access in the boiler
for maintenance operations,
the minimum distances shown
below must be respected (fig.
1):
To facilitate installation, the
boiler is supplied with a
template for advance location
of connections to pipes. In this
way, you may simply hook up
the boiler when wall work is
completed (fig.2).
Installation Instruction
a)
with a spirit level, draw a
line on the wall on which
the boiler will be installed
(fig. 1);
b)
position the top of the
template on the line drawn
with the spirit level
(respecting the distances –
see fig. 1) than mark the
three points for insertion of
the 3 screw anchors or wall
anchors for fixing the boiler
hanging bracket (choose
proper anchors according
to the wall type);
c)
fix the hanging bracket
d)
make connections to the
hot and cold water supply,
to the gas pipe and to the
heating system with the
fittings. Connect pipes and
valves as shown in the
picture;
e)
position the boiler paying
attention to hang it to the
hanging bracket and make
final connections;
Fig. 2
75
5
87
344
82
R
55.5
53
80
0
102
C
F
70
80
G
A
55.5
286
WITH BRACKET MOD. 1
CON STAFFA MOD. 1
MOD. 2
KIT H
MOD. 1
MOD. 2
MOD. 1
KIT A
82
53
R
HEATING RETURN ¾”
G
GAS ½”
C
HOT WATER ½”
F
COLD WATER ½”
A
HEATING FLOW ¾”
FIXING KIT
Fig. 3
Fig. 1
WATER CONNECTIONS
To facilitate installation, the boiler is equipped with a fittings kit (see fig. 3).
IMPORTANT:
Before connecting the heating system pipes, carefully clean the system to
prevent residual dirt from entering into circulation and negatively affecting boiler
function. Install a funnel with discharge under the safety valve (calibrated to 3
bar) to collect water in case of leaking due to overpressure. No safety valve is
needed for the domestic water circuit, but be sure that pressure does not
exceed 6 bar.
Fig. 4
•
avoid using pipelines of reduced diameter;
•
avoid the use of tight bends and adapters in important sections;
•
clean out the system thoroughly before connecting up the boiler in order to eliminate any residue left in the pipes and radiators;
N.B.:
Make sure that the water and heating pipes are not used as earth connections for electrical apparatus.
WARNINGS
Boilers can be installed externally, in a partially protected place (balcony – see fig. 4) in conformity with local Building Regulation and if the
outside minimum temperature is not lower than –10°C. The manufacturer is not responsible for external installations where the outside
temperature is lower than – 10°C or not in conformity with above instructions.