background image

USER INSTRUCTIONS

 

 

7

9.  Frost Protection 

 

The boiler is protected from freezing by electronic board settings and special functions that provide the starting of 

the burner to heat all the interested parts, when their temperature drops below the minimum preset values. 

 
This function is enabled if:  

–  the boiler is electrically power supplied;  
–  the gas supply is open; 
–  the system pressure is that required; 
–  the boiler is not locked out. 

  

In case of boiler parts locked out because of freezing, do not switch the boiler ON and immediately 

call the Service Centre. 
 

 

10. Maintenance 

 

In order to ensure that the boiler operates efficiently and safely, it is recommended that the appliance is inspected 
by a suitably competent technician at least once a year

.  

A regular maintenance is always source in management system savings.  

 

 

11. Recycling 

 

The appliance packaging is mainly made of 
recyclable materials.  
 
The appliance and all its accessories must be 
disposed of appropriately differentiated  
in compliance with the relevant standards.

 

 

The symbol indicates the inability to dispose of 

this product as domestic waste. 

The correct disposal of this product will help to 

prevent potential negative consequences for the 

environment and people health.

 

Summary of Contents for RSA 32/25

Page 1: ...5 RAD ING MAN UT 1412 1 DIGITECH TR MIAH6 E04 Technical specification RADIANT BRUCIATORI S p A Montelabbate PU ITALY ENGLISH User Manual for model RSA 32 25 Wall mounted storage combi boiler premix co...

Page 2: ...arting up the boiler pagina 3 4 INFO Menu pagina 3 5 Boiler functioning modes pagina 4 6 Filling the system pagina 5 7 Diagnostics Error codes pagina 5 8 Switching OFF the boiler pagina 6 9 Frost Prot...

Page 3: ...not attempt to start it All maintenance and gas conversion operations MUST BE CARRIED OUT BY PROFESSIONALLY QUALIFIED PERSONNEL Should any part of the boiler freeze up do not attempt to light it unde...

Page 4: ...ERRORS 3 MODE SELECTION BUTTON SUMMER ONLY WINTER ONLY SUMMER WINTER OFF 4 RESET BUTTON ERROR RESET FLUE TEST FUNCTION ACTIVATION CHIMNEY SWEEPER KEEP IT PRESSED FOR 7 SECONDS 5 DOMESTIC HOT WATER TE...

Page 5: ...nce pressed the parameter number will appear on the left side of the display and the associated parameter value will appear on the centre of the display Use and buttons of Heating Temperature setting...

Page 6: ...ion to SUMMER WINTER mode press the MODE SELECTION button 3 fig 1 The boiler will work for both central heating D H W systems The SUMMER WINTER mode setting of the boiler is signalled by symbols lit c...

Page 7: ...he display disappears the boiler will restart automatically If the problem persists Call the Service Centre Code E02 Safety Thermostat tripped Press Reset button on the control panel to reset the erro...

Page 8: ...0 Electric power supply out of the operation range Call the Service Centre Code F08 Frost protection function central heating circuit ON Wait for the completion of the operation Code F09 Frost Protect...

Page 9: ...d immediately call the Service Centre 10 Maintenance In order to ensure that the boiler operates efficiently and safely it is recommended that the appliance is inspected by a suitably competent techni...

Page 10: ...THE COMPANY RESERVES THE RIGHT TO APPLY VARIATIONS WITHOUT PRIOR NOTIFICATION NEITHER WILL THE COMPANY BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS HANDBOOK DERIVING FROM PRINTING OR TRANSLATION E...

Reviews: