MAINTENANCE INSTRUCTIONS
33
5.3 Setting the parameters
P
ARAMETER
P00
–
SELECTS THE TYPE OF BOILER
To enter the parameters menu, follow the previously described procedure
(
see paragraph
5.2 ‘Accessing the parameters menu’
- steps 1-5).
6.
Use ‘
’ and ‘
’
buttons (D.H.W temperature setting)
to modify the
value of the parameter:
00 = Instantaneous boiler (w/dual circuit exchanger)
01 = Instantaneous boiler (w/secondary d.h.w plate exch.)
02 = Storage cylinder boiler
03 = Storage cylinder boiler with Comfort function
04 = Instantaneous boiler (w/secondary d.h.w plate exch.) with Comfort
function
05 = Only heating boiler
7.
Press mode selection button ‘
’ to confirm and to render the new
adjustment operative. The parameter number (P00) will appear on the
display.
8.
To exit from the parameters menu, press simultaneously ‘
’ and ‘
’
buttons.
P
ARAMETER
P01
-
S
ELECTS THE TYPE OF GAS SUPPLY
To enter the parameters menu, follow the previously described procedure
(
see paragraph
5.2 ‘Accessing the parameters menu’
- steps 1-5).
6.
Use ‘
’ and ‘
’ buttons (D.H.W temperature setting)
to modify
the value of the parameter
00 = Natural Gas
01 = LPG
7.
Press mode selection button ‘
’ to confirm and to render the new
adjustment operative. The parameter number (P01) will appear on the
display.
8.
To exit from the parameters menu, press simultaneously ‘
’ and ‘
’
buttons.
P
ARAMETER
P02
-
S
ETS THE CENTRAL HEATING TEMPERATURE
To enter the parameters menu, follow the previously described procedure
(
see paragraph
5.2 ‘Accessing the parameters menu’
- steps 1-5).
6.
Use ‘
’ and ‘
’ buttons (D.H.W temperature setting)
to modify
the value of the parameter:
00 = standard (30-80°C)
01 = reduced (25-45°C) for under-floor heating
7.
Press mode selection button ‘
’ to confirm and to render the new
adjustment operative. The parameter number (P02) will appear on the
display.
8.
To exit from the parameters menu, press simultaneously ‘
’ and ‘
’
buttons.
01
P00
00
P01
01
P02
Summary of Contents for RSA 24 /8