background image

USER INSTRUCTIONS

 

 

4

Diagnostics – Error codes: 
 

This  paragraph  contains  a  list  of  error  codes  that  the  boiler may  generate  on  the  display  7  (see  “Control  panel”) 
together with the relative indications and the operations that the user can carry out to reset the boiler. 

 

If  the  problem  re-occurs  after  the  following  actions  have  been  taken,  call  an  authorised  Service 
Centre. 

 

_

E01

E01

E01

E01

  

Ionisation block

 

Code E01 lit continuously on the display.   

  Check that the gas valve on the boiler and gas meter are open and that there is gas in the mains supply (or in 

the tank).  

  Switch off then switch on the appliance using switch 1 (see “Control panel”) on the control panel. 

  When  the error code on the display disappears, the boiler will restart. 

If the problem persists, Call the Service Centre. 

 

_

E02

E02

E02

E02

_  Safety Thermostat tripped

 

Code E02 lit continuously on the display.  Call the Service Centre. 

 

_

E03

E03

E03

E03

_  Flue Gas Thermostat tripped

 

Code E03 lit continuously on the display.  Call the Service Centre. 

 

_

h2o

h2o

h2o

h2o

_  Low Water Pressure Alarm  

Code H2O lit continuously on the display.   

  Fill the system until the pressure gauge reches 1.0 bar. 

  The boiler will restart automatically. 

If the problem persists, Call the Service Centre.

 

 

_

E05

E05

E05

E05

 

Heating Sensor malfunction

 

Code E05 lit continuously on the display.  Call the Service Centre. 

 

_

E16

E16

E16

E16

_  Electric Fan Malfunction  

 

Code E16 lit continuously on the display.  Call the Service Centre. 

 

_

E22

E22

E22

E22

_

  

Parameter programming request   

Code E22 lit continuously on the display.  Call the Service Centre. 

 

_

E35

E35

E35

E35

_

  

Flame Detection Malfunction   

Code E35 lit continuously on the display.  Call the Service Centre. 

 

N.B. If the boiler is to be left unused for a long period of time, the user must do one of the following: 

  Make the boiler safe by disconnecting all the power supplies (electricity and gas), and draining the heating 

system and the condensate trap. 

  Leave the boiler in standby, leaving the electricity and gas supplies connected and, consequently the anti-freeze 

function.

Reviews: