2. MAINTENANCE
SUPPOR
T
C
ENTRE
CODE
FAULT
POSSIBLE CAUSE
SOLUTION
RESET
E02
SAFETY THERMOSTAT
(95°C)
THERMOSTAT CABLE
DISCONNECTED;
CHECK THE WIRING:
AUTOMATIC.
BROKEN THERMOSTAT.
REPLACE IT.
E03
FUMES SAFETY
THERMOFUSE (102°C)
THERMOFUSE BROKEN;
REPLACE IT;
MANUAL
RESET
(PRESS THE RESET ‘
’ KEY).
THERMOFUSE CABLE
DISCONNECTED.
CHECK THE WIRING.
E04
WATER MISSING IN THE
SYSTEM
INSUFFICIENT WATER
PRESSURE INSIDE THE SYSTEM
(LOWER THAN 0.3 BAR);
LOAD THE SYSTEM;
AUTOMATIC.
WATER PRESSURE SWITCH
CABLE DISCONNECTED;
CHECK THE WIRING;
WATER PRESSURE SWITCH
BROKEN.
REPLACE IT.
E05
HEATING PROBE
BROKEN OR INCORRECTLY
CALIBRATED PROBE
(RESISTANCE VALUE 10
KOHM AT 25 °C NTC);
REPLACE IT;
AUTOMATIC.
DISCONNECTED OR WET
PROBE CONNECTOR.
CHECK THE WIRING.
E06
DOMESTIC CIRCUIT PROBE
BROKEN OR INCORRECTLY
CALIBRATED PROBE
(RESISTANCE VALUE 10
KOHM AT 25 °C NTC);
REPLACE IT;
AUTOMATIC.
DISCONNECTED OR WET
PROBE CONNECTOR.
CHECK THE WIRING.
E10
LOW FLOW RATE
THE FLOW RATE VALUE
DETECTED BY THE
FLOWMETER IS LOWER
THAN THE VALUE SET AT
PARAMETER P33.
INCREASE THE FLOW RATE OR LOWER
THE VALUE AT PARAMETER P33.
AUTOMATIC.