1. INSTALLATION
INST
ALLER
III (
a
)
- KIT M&G HORIZONTAL CO-AXIAL
SYSTEM Ø3.1/4.9
in
(Ø80/125
mm
) INTERNAL
POLYPROPYLENE DUCT ADJUSTABLE AT 360°.
It allows exhaust and air intake from external wall.
Suitable only for condensing unit.
It allows exhaust and air intake for combustion
through co-axial ducts, the external one for air
intake, the plastic internal one for exhaust.
PLEASE SEE THE MAXIMUM EXHAUST LENGTH
IN THE TABLE IN 1.1.21 “ALLOWABLE VENT
LENGTHS”.
The maximum exhaust length (or linear reference
length) can be calculated by summing the length
of the linear tube.
When terminating horizontally, install an elbow at
the end of the terminal. For area where snow is
a concern it is recommended to point the elbow
downwards.
90°
L= 3.9 in(100 mm)
Ø4.9 in (Ø125 mm)
Ø3.1 in (Ø80 mm)
INSTALLATION
fig. 20
fig. 21