3. USE  

USER

3.1.4. INFO MENU DISPLAY DATA

To view the boiler data from info menu you just have to press the INFO ‘

’ key. The info code will be 

displayed on the left side of the screen and its relative value will be displayed on the centre of the screen. 
Use keys ‘

’ and ‘

’ of the heating circuit 

 to scroll through the list of displayed data. To exit display 

mode press the INFO ‘

’ key.

LIST OF DISPLAYED DATA

INFO CODE

ICON

DESCRIPTION

d0

DOMESTIC CIRCUIT PROBE TEMPERATURE

d1

EXTERNAL PROBE TEMPERATURE

d2

FAN SPEED 

d3

BOTTOM AREA PROBE TEMPERATURE [IF AREA BOARD INSTALLED]

d4

RETURN PROBE TEMPERATURE

d5

SOLAR COLLECTOR TEMPERATURE [IF SOLAR BOARD INSTALLED] (SCS)

d6

SOLAR BOILER TEMPERATURE (BOTTOM) [IF SOLAR BOARD INSTALLED] (SBSI)

d7

SOLAR BOILER TEMPERATURE (TOP) [IF SOLAR BOARD INSTALLED] (SBSS)

d8

SOLAR COLLECTOR PROBE TEMPERATURE 2 [IF SOLAR BOARD INSTALLED] (SCS2)

d9

EXTRA SOLAR BOILER TEMPERATURE [IF SOLAR BOARD INSTALLED] (SBS3)

Summary of Contents for R1K 18

Page 1: ...R1K 18 RAD ING Manuale 1706 1_V3 Installation Use and Maintenance Manual for model 0476 R1K 18 Premix condensing system boiler only heating...

Page 2: ...s temperature at nominal heat capacity C 73 65 Fumes temperature at minimum heat capacity C 65 7 CO2 at nominal heat capacity G20 9 3 9 1 CO2 at minimum heat capacity G20 9 8 8 CO2 at nominal heat cap...

Page 3: ...ax discharge length 80 125 Vert Co ax m 12 Max discharge length 50 50 Vert Split m 10 Max discharge length 60 60 Vert Split m 32 Max discharge length 80 80 Vert Split m 60 Max discharge length 50 Vert...

Page 4: ...tary heater enabled PCHP100 Sup100 kW RU FRJHQHUDWLRQ VSDFH KHDWHUV OHFWULFDO HI FLHQF At rated heat output of cogeneration space heater with VXSSOHPHQWDU KHDWHU GLVDEOHG el CHP100 Sup0 At rated heat...

Page 5: ...HQHUJ HI FLHQF wh Daily fuel consumption Qfuel kWh Annual fuel consumption AFC GJ Contact details Tel 39 0721 9079 1 fax 39 0721 9079299 e mail info radiant it http www radiant it Name and address of...

Page 6: ...ELECTRODE 5 ELECTRIC FAN 6 AIR RELIEF VALVE 7 SAFETY VALVE 3 bar 8 MODULATING PUMP 9 GAS VALVE 10 SYSTEM DRAINING TAP 11 SAFETY THERMOSTAT 12 HEATING PROBE 13 LIGHT UP ELECTRODE 14 EXPANSION TANK 15...

Page 7: ...FUMES SAFETY THERMOFUSE 2 HEAT EXCHANGER 3 BURNER UNIT 4 ELECTRIC FAN 5 GAS VALVE 6 AIR RELIEF VALVE 7 CIRCULATOR 8 SAFETY VALVE 3 bar 9 SYSTEM DRAINING TAP 10 HEATING PROBE 11 SAFETY THERMOSTAT 12 E...

Page 8: ...AND OTHER INFORMATION see chapter INFO MENU DISPLAY HOLD FOR 5 SECONDS IN OFF OPERATING MODE TO VIEW THE LAST 5 FAULTS 3 OPERATING MODE SELECTION KEY ONLY HEATING OFF 4 RESET KEY FAULTS RESET CHIMNEY...

Page 9: ...EMPERATURE DISPLAY d7 6 EXTERNAL PROBE INSTALLED EXTERNAL PROBE TEMPERATURE d1 7 TEMPERATURE DISPLAY SET POINT PARAMETER VALUE 8 OPEN THERM COMMUNICATION PRESENT REMOTE CONTROL AREA CONTROL UNIT 9 INS...

Page 10: ...isplayed data To exit display mode press the INFO key LIST OF DISPLAYED DATA INFO CODE ICON DESCRIPTION d0 DOMESTIC CIRCUIT PROBE TEMPERATURE d1 EXTERNAL PROBE TEMPERATURE d2 FAN SPEED d3 BOTTOM AREA...

Page 11: ...pressure gauge M fig 1 that the system pressure reaches 1 2 bar see fig 2 After performing this operation make sure that the loading tap R fig 1 is properly closed After the water pressure reset the b...

Page 12: ...SET THE FAULT AS SOON AS THE ERROR CODE DISAPPEARS FROM THE DISPLAY THE BOILER WILL START AUTOMATICALLY IF THE BLOCK PERSISTS CONTACT THE TECHNICAL SUPPORT CENTRE E03 FUMES SAFETY THERMOFUSE 102 C CON...

Page 13: ...E MAIN SWITCH AND THEN RESTORE IT AS SOON AS THE ERROR CODE DISAPPEARS THE BOILER WILL RESTART AUTOMATICALLY IF THE BLOCK PERSISTS CONTACT THE TECHNICAL SUPPORT CENTRE E35 RESIDUAL FLAME PRESS THE RES...

Reviews: