44
SFK 57 - RAD - ING - Inst. Manual - 2210.1_SKM1_firm.L188i58_CSA
2. FIRST START-UP
SUPPOR
T CENTER
PARAMETER
DESCRIPTION
RANGE
FUNCTION
P05
RECIRCULATION DIFFERENTIAL ACTIVATION
THROUGH THIS PARAMETER YOU CAN ANTICIPATE
THE RECIRCULATION FUNCTION, COMPARED TO THE
RECIRCULATION SET POINT PRESET BY THE END-USER, BY
MODIFYING THE TEMPERATURE DIFFERENCE.
5 - 15
VALUE EXPRESSED IN °C
P06
FAN MINIMUM SPEED ADJUSTMENT
THROUGH THIS PARAMETER YOU CAN SET THE FAN MINIMUM
SPEED CORRESPONDING TO THE MINIMUM POWER OF THE
BURNER.
THE VALUE IS PRE-SET BASED ON THE SET POWER (SEE
PARAMETER P00) AND ON THE GAS TYPE (SEE PARAMETER
P01).
43 - 255
VALUE EXPRESSED IN HERTZ
(1HZ = 30 RPM)
P07
FAN MAXIMUM SPEED ADJUSTMENT
THROUGH THIS PARAMETER YOU CAN SET THE MAXIMUM FAN
SPEED CORRESPONDING TO THE MAXIMUM POWER OF THE
BURNER.
THE VALUE IS PRE-SET BASED ON THE SET POWER (SEE
PARAMETER P00) AND ON THE GAS TYPE (SEE PARAMETER
P01).
43 - 270
VALUE EXPRESSED IN HERTZ
(1HZ = 30 RPM)
P08
STARTING STEP ADJUSTMENT
THROUGH THIS PARAMETER YOU CAN SET THE FAN SPEED
DURING THE START-UP.
THE VALUE IS PRE-SET BASED ON THE SET POWER (SEE
PARAMETER P00) AND ON THE GAS TYPE (SEE PARAMETER
P01).
43 - 255
VALUE EXPRESSED IN HERTZ
(1HZ = 30 RPM)
P09
D.H.W RUN-DOWN
THROUGH THIS PARAMETER YOU CAN SET THE TIME NECESSARY
FOR THE WATER HEATER TO REACH THE MINIMUM SET POWER,
AFTER THE BURNER START-UP.
2 - 15
VALUE EXPRESSED IN
SECONDS (FACTORY SET AT 8
SECONDS)
P10
TYPE OF UNIT SELECTION
0 - 1
0 = °C - L/MIN
1 = °F - GPM