background image

Ref No.

052017 

Important Notes 

Cleaning 
And Storage

 

Please make sure the probe is clean to ensure an accurate reading. 

 

The probe lens is the most delicate part of the thermometer. Use with care when cleaning the probe lens to avoid damage. 
a. Use the 70% alcohol swab or the soft cotton moistened with the 70% alcohol to clean the probe lens. 
b. Allow the probe to fully dry for at least 1 minute. 
c. Keep the unit dry and away from any liquids and direct sunlight.   

        d.

 

Storage temperature range: It should be stored at room temperature between -20~+50°C,

 

RH

85% 

e. The Probe should not be submerged into liquids. 

  Holding the thermometer too long may cause a higher ambient temperature reading of the probe. 

        This could make the body temperature measurement lower than usual.

 

Battery replacement 
 

 

This device is supplied with one lithium cell CR2032x1. 
1. Open the battery cover: Insert a pointed object into battery cover pick hole. At the same time, use thumb to push battery cover out.   

(See Figure 1) 

2. Hold the device and flip the battery out with a small screwdriver. (See Figure 2) 
3. Insert a new battery under the metal hook and press down until you hear a “click” sound. (See Figure 3) 
4. Replace the battery cover 

 

 

The positive (+) side up and the negative (-) side pointed down.   

 

 

 

Trouble shooting: 

Error Message 

Problem 

Solution 

 

Error 5~9, the system is not functioning properly. 

Unload the battery, wait for 1 minute and repower it. If the message 

reappears, contact the retailer for service. 

 

Measurement before device stabilization.

 

Wait until all the icons stop flashing.

 

 

The ambient temperature is not within the range between 10

o

C and 40

o

C (50

o

F ~104

o

F). 

Allow the thermometer to rest in a room for at least 15 minutes at room 
temperature: 10

o

C and 40

o

C (50

o

F ~104

o

F). 

 

Temperature taken is higher than +42.2

o

C (108°F) 

Please select the target within specifications. If a malfunction still exists, 
please contact the nearest retailer. 

 

Temperature taken is lower than +34

o

C (93.2°F) 

 

Device cannot be powered on to the ready stage. 

Change with a new battery. 

 

Warranty:

 

Warranty: 12 months   
Manufacture Date: as the serial number (please open the battery cover, it is shown on the inside of the device.)

 

 

Ex.SN:E512A000001, the first “E” is External, the second number “5” is the last number of manufacture year, the third and the fourth number “12” is the manufacture 
month, the others is the serial number.

 

Note: The thermometer is calibrated at the time of manufacture. If at any time you question the accuracy of temperature measurements, please contact the 

dealers or nearest service address. 

 

Warning: No modification of this equipment is allowed. 

  Please read the instructions for use       

  BF type applied part 

 

Radiant Innovation Inc.     
Http://www.radiantek.com.tw 
Add: 1F, No.3, Industrial East 9

th

 Road,   

Science-Based Industrial Park, HsinChu, Taiwan 300. 

Medical Technology Promedt Consulting GmbH   
Add: Altenhofstrasse 80, D-66386 St. Ingbert, 
Germany 

 

 

 

Figure 1 

 

 

  Figure 2 

 

 

Figure 3 

Reviews: