![Radian Bantam Plus RB-2 Series Getting Started Manual Download Page 30](http://html1.mh-extra.com/html/radian/bantam-plus-rb-2-series/bantam-plus-rb-2-series_getting-started-manual_3227189030.webp)
Bantam Plus Getting Started Guide v6
30
Radian Research, Inc.
4.2.1 Conducting a Meter Test with the Bantam Plus Integrated Socket
The test procedure described below assumes the
meter is removed from the meter socket and
inserted into the Bantam Plus integrate socket and
the internal Sensor Pro optic sensor is used. For
detailed explanation on using Bantam Plus to test
meters in the meter panel using the optional RB-
MTA see
section 4.2.2
Follow these steps to conduct a Form 2S Meter test with the RB-2X Bantam Plus
Portable Test System:
1.
Power the Bantam Plus using the instructions described in section
4.1.1 or 4.1.2. You will hear an audible tone three times from
internal RD Reference Standard during power-up this indicate the
internal reference standard is operational.
2.
See Figure 9 for a Bantam Plus screen tour.
3.
For the purpose of this exercise we will assume no „Profiles‟ have
been created. Select „METER TEST‟
Figure 9
Bantam Plus
Screen Tour
N
OTE
Profile TAB – accesses
addition profile pages. A
maximum of 30 profiles can
be assigned by the operator.
Select ‘Meter Test’ to bypass a
Profile and run a meter test
Profile keys are short cuts
to pre-assigned meter
information. Meter
information can be
assigned to each Profile
from the Edit Profile key
and stored in non volatile
RAM.
Before powering down the
Bantam Plus Select
‘Shutdown to exit Windows
Select Main Menu Tab to view
additional ‘Administration’
and ‘Utilities’ Application
Icons