TECHNICAL DATA
SHEET
MICT0300003
Series
DSX
CONCENTRIC TWINAX CONTACT 616096017
ASSEMBLY INSTRUCTIONS FOR F2709/9 CABLE
Issue
14 APRI 2005
Page
1/4
14/04/05
Selector position 6 was 7 ;CHANGE DRAWING
B Gombert
C.Lahoreau
05JAN05
Was RP57839 ; revision per wish Customer
B.Gombert
C.Lahoreau
CREATION
NAME : B.GOMBERT
DATE : 29/09/04
APPR. : L.LAHOREAU
ISSUE
REVISIONS
NAME
APPROVED
FOR ENVIRONMENTAL APPLICATION, BEFORE STRIPPING, SLIDE SEALING SLEEVE AND SEALING BUSHING
OVER CABLE
STEP 1/
TRIM CABLE JACKET TO LENGTH INDICATED
STEP 2/
SLIDE THE FERRULE OVER THE CABLE. CUT THE HIGH IMMUNITY RIBBON IF ANY
FOLD BACK BRAID OR BRAIDS OVER THE FERRULE AS INDICATED
CUT BRAID OR BRAIDS AS SHOWN
CUT ROD FILLERS
STRIP THE N°2 CONDUCTOR (WARNING : COLOR POLARIZATION PER INDICATE )
A
4,50 (.177)
B
3,20 (.126)
2,20 (.087)
C
4,00 (.157)
3,50 (.138)
Sealing sleeve
Sealing bushing
Inner braid
Jacket cable
WHITE
Cut outer braid and 2 aluminum ribbons
On the right
N°1 CONDUCTOR
(see step 4/ )
N°2 CONDUCTOR
BRAIDS
A
26 ,00 (1.023)
24,00(.945)