background image

i

In the case of power failure:
If you wish to manually operate the door in 

the event of a power cut, you must pull the 

emergency release cable so that this releases 

the door from the door operator.  

After that you can move the door freely.

Manual door operation 

1.

If power recovers:
Operate the hand transmitter or the wall 

switch.

1.

NOTE

Engagement happens automatically.

There is a risk of injury. The door can fall 

down uncontrollably when released (e.g. if 

the door is not balanced)

 Close or open the door fully after each release.

 The emergency release is not intended for  

  „everyday use“.

30

EN

Summary of Contents for RolloPort S2

Page 1: ...Item no 4201 70 61 4202 70 61 VBD 543 02 01 23 EN Garage door drive RolloPort S2 Translation of the Original Operating and Assembly Manual...

Page 2: ...ric shock This sign warns of danger when working on electrical connections components etc It requires that safety precautions be taken to protect the health and life of the person concerned This conce...

Page 3: ...allation of the fixing bracket 5 at the door operator head 7 18 C Installation of the door bracket 8 19 D Installation of the middle support clip 13 20 E Installation on the ceiling with perforated br...

Page 4: ...r including lighting 2 Hand transmitter 3 LED 4 1st hand transmitter button 5 2nd hand transmitter button 6 Set button S 7 Display 8 Button for adjustment 9 Button for adjustment 10 Programming button...

Page 5: ...15 mm 1 x Screw 6 x 80 mm with hexagon nut 1 x Bolt 8 x 20 mm 1 x Securing bolt 2 x 20 mm 4 x Screw 8 x 20 mm with hexagon nut and plain washer 6 x Wall plug 10 mm 6 x Hexagon head screw 8 x 60 mm 1 x...

Page 6: ...stationary All work performed on electrical equipment is associated with a risk of electric shock and electrocution Have all work on electrical equipment and on the door operator carried out by a qua...

Page 7: ...der proper operation A220 240V 50 60Hzpowersupplymustbeavail able at the place of installation Comply with all maintenance intervals Proper use also includes the regular inspection of the door and its...

Page 8: ...y existing safety equip ment which deviate from the measures described in this manual Such alterations endanger the operating safety The garage door operator must not be used in commercial establishme...

Page 9: ...mergency release cable in the case of power failure Automatic closing function The automatic closing time of the door can be set from 30 to 240 seconds refer to page 25 26 2000 cycle alarm When the op...

Page 10: ...nal open position Place a 50 mm high object e g a wooden block in the direction of travel of the door Close the door by actuating the hand trans mitter If the door hits an obstruction when closing the...

Page 11: ...egular checks of wearing parts There is a risk of injury due to defective or worn components Check the system therefore regularly for signs of wear damage or lack of balance of the door Do not use the...

Page 12: ...structions carefully An incorrect installation can lead to serious injuries Faulty installation can result in serious ac cidents and injuries Fit the actuator for the emergency release at a height of...

Page 13: ...cks Remove all vertical and horizontal door locks and catches IMPORTANT Keep the old door locks in a safe place In the event that you should remove the garage door operator you will have to fit these...

Page 14: ...ong Determine the distance between the top edge of the door and the ceiling Close the door slowly and measure the distance between the top edge of the door and the ceiling NOTE The minimum distance sh...

Page 15: ...ive Tension the drive chain 1 Connector 1 Fixing plates Connector 2 1 2 3 1 2 2 Lay the two end pieces with the pre assembled chain on the ground with the chain lying as straight as possible be tween...

Page 16: ...ver the connector 5 Place the two fixing brackets 2 over the rail 4 and screw these firmly onto the door operator housing with the enclosed self tapping hexagon screws 6 x 15 mm 1 2 3 4 5 Key 1 Self t...

Page 17: ...further inward The full rail length can then be used as a result NOTE When fitted to the ceiling the distance to the door leaf must be a maximum of 25 cm Otherwise perforated brackets must be used se...

Page 18: ...6 x 80 mm to the header bracket 1 B Installation of the fixing bracket 5 at the door operator head 7 1 Push the fixing bracket 5 onto the rail 4 as close to the door operator head 7 as possible Mark...

Page 19: ...ey 8 Door bracket 9 Bolt 8 x 20 mm 10 Self tapping hexagon screw 6 x 15 mm 11 Securing bolt 2 x 20 mm 12 Door connector bent 8 10 11 9 12 Place the door bracket 8 on the top edge of the garage door an...

Page 20: ...slipping out 3 4 C Installation of the door bracket 8 5 9 1 13 14 Fit the middle support 13 clip at a suitable place as near as possible to the middle point between the door and the door operator hea...

Page 21: ...e light goes on and the unit gives a single beep and the display shows 0 at regular intervals 1 Establish operational readiness of the door Important notes after installation u Afterinstallation ensur...

Page 22: ...setting order specified 1 Press P for approx 5 seconds Setting limits setting the upper limit 2 The door operator beeps and shows 1 3 Press P 1 flashes 5 The door opens or closes 6 If the door has mo...

Page 23: ...ve fulfilled the basic settings required for safe operation If you do not require any further settings you must conclude programming as specified in method 1 on page 27 in order to adopt the basic set...

Page 24: ...Press or press to select the stage After a resetting of the power level it is absolutely necessary to repeat the reference run for power limiting and to conclude the programming again u During the ref...

Page 25: ...ng NOTE Before the door closes automati cally the door operator beeps for 20 seconds At the same time the light flashes When the door starts closing the light shines durably and it beeps permanently A...

Page 26: ...nt of lubricant to all moving parts regularly 2 Press press several times if necessary until 7 is displayed 2000 cycle alarm setting 3 Press P the display is 0 0 off factory setting 4 Press the displa...

Page 27: ...rogramming 2 Keep P pressed for 5 seconds 3 0 will be displayed at regular intervals in order to conclude the programming and set the door operator into an idle state Method 1 Carry out this method wi...

Page 28: ...hand transmitter After that you can also register further hand transmitters You can register a maximum of 16 additional transmitters 1 Press S and keep pressed 2 As acknowledgement a green point will...

Page 29: ...ctronics If the external buttons are not connected properly the operational safety of the equipment is at risk Always mount the internal button programming button etc outside the reach of movable part...

Page 30: ...tor After that you can move the door freely Manual door operation 1 If power recovers Operate the hand transmitter or the wall switch 1 NOTE Engagement happens automatically There is a risk of injury...

Page 31: ...oor operator has been disengaged refer to page 30 i Notes for use Check the operator system to determine whether it moves smoothly the first time the garage door operator is used After some time in us...

Page 32: ...er doors 76 65 kg for one piece doors 220 240 10 20 40 Guide rail and available sizes Item no max total lenght Height of travel max lifting height 4201 70 61 3140 mm 2310 mm 2250 mm 4202 70 61 3740 mm...

Page 33: ...elease may have been triggered There is not sufficient lubricant be tween the rail and the chain slide after long use The chain is loose due to long use without lubricant between the rail and the chai...

Page 34: ...ry directive and 2014 53 EU Radio Equipment Directive The full text of the EU declaration of conformity is included with the product and is kept on file by the manufacturer RADEMACHER Ger te Elektroni...

Page 35: ...i 35 EN...

Page 36: ...Subject to technical changes printing errors and mistakes Illustrations not binding RADEMACHER Ger te Elektronik GmbH Buschkamp 7 46414 Rhede Germany...

Reviews: