RADEMACHER 3514 06 63 Instruction Manual Download Page 3

3

EN

i

Contents

Dear Customer, ...................................................................

2

1.    This manual... ......................................................................

4

1.1    How to use this manual .....................................................................4

2.    Hazard symbols ..................................................................

5

2.1    Levels of danger and signal words .................................................5
2.2    Symbols and depictions used ..........................................................6
2.3    Glossary - definition ............................................................................7

3.    Included in delivery ...........................................................

8

4.    Overview and connections ...............................................

9

4.1    Operating buttons and indicator light ...................................... 10

5.    Functional description ...................................................

11

5.1    Functional characteristics............................................................... 12

6.    Technical specifications .................................................

14

7.    Safety instructions ..........................................................

17

7.1    Intended use ....................................................................................... 17
7.2    Improper use ....................................................................................... 18
7.3    Expert knowledge required by the installer ............................ 19

8.    Safety instructions for the electrical connection ............

20

8.1    Important information regarding the electrical connection ... 21
8.2     Connecting and installing the DuoFern  

Motor Actuator 9471-2 .................................................................... 22

8.3    Connection diagram (e.g. for 24 V DC motors) ....................... 23

9.    Logging DuoFern transmitters on / off .......................

24

9.1    Logging on and off via radio code .............................................. 25

10.   Deleting all settings (reset) ...........................................

26

11.   Dismantling ......................................................................

27

12.   Simplified EU declaration of conformity .....................

28

13.   Warranty terms and conditions ....................................

29

Summary of Contents for 3514 06 63

Page 1: ...VBD 621 22 04 21 Item no 3514 06 63 EN DuoFern Motor Actuator 9471 2 Instruction manual for the electrical connection and for commissioning Type 9471 2 ...

Page 2: ...k you for the trust you have placed in us RADEMACHER products have been developed with the greatest possible convenience in mind Having applied uncompromising quality standards and thorough testing we are proud to be able to present this innovative product to you It s brought to you by all the highly quali fied personnel here at RADEMACHER ...

Page 3: ...ications 14 7 Safety instructions 17 7 1 Intended use 17 7 2 Improper use 18 7 3 Expert knowledge required by the installer 19 8 Safety instructions for the electrical connection 20 8 1 Important information regarding the electrical connection 21 8 2 Connecting and installing the DuoFern Motor Actuator 9471 2 22 8 3 Connection diagram e g for 24 V DC motors 23 9 Logging DuoFern transmitters on off...

Page 4: ...ns Please also read the instruction manual for the appliance being used This manual is part of the product Please store it in an easily accessible place When passing the DuoFern Motor Actuator 9471 2 on to a third party this manual must be passed on as well Damage resulting from non compliance with these instructions and safety instructions will void the guarantee We assume no liability for any co...

Page 5: ...s situation 2 1 Levels of danger and signal words DANGER This hazard will lead to serious injury or death if not avoided WARNING WARNING This hazard may result in serious injury or death if not avoided CAUTION This hazard may result in minor or moderate injury if not avoided ATTENTION This hazard may lead to property damage i ...

Page 6: ...6 EN 2 2 Symbols and depictions used Depiction Description 1 Steps to be taken 2 Itemisation 1 or a Lists i Further useful information Please read the respective manual i ...

Page 7: ...patible products WR ConfigTool RADEMACHER software for programming the DuoFern Manual Control incl automatic software updates for the DuoFern Manual Control HomePilot The HomePilot is a central control unit for RADEMACHER radio products ELV Extra low voltage SELV Safety extra low voltage ...

Page 8: ...8 EN i 3 Included in delivery Included in delivery a 1 x DuoFern Motor Actuator 9471 2 incl antenna b 1 x Instruction manual not illustrated a ...

Page 9: ...f an external switch button for manual control on site 2 Potential free relay contact rotation direction down Connection of an electrical appliance e g a motor 3 Potential free relay contact rotation direction up Connection of an electrical appliance e g a motor 4 230V 50 Hz Connection of the supply voltage 3 ...

Page 10: ...atus display green flashing constantly lit up flashes briefly Connection is active Connection or disconnection was successful Control command received red flashing constantly lit up Disconnection is active Connection or disconnection was not successful 7 Disconnect button Logging off from the DuoFern radio network or a DuoFern transmitter Reset to the default factory settings 5 6 7 ...

Page 11: ... safety for the 230 V 50 Hz supply voltage of the actuator Use in the DuoFern network You can integrate the device into a DuoFern radio network for example to use a wide range of the functions of DuoFern sensors and DuoFern transmitters such as the HomePilot Manual operation on site An additional external locking roller shutter switch or button can be connected to enable manual operation on site I...

Page 12: ... Manual mode on off on off off 4 Automatic timer on off on off on 5 Random function 6 Dawn function 7 Automatic dawn function on off on off off 8 Automatic dusk function 9 Automatic dusk function on off on off off 10 Sun function 11 Automatic sun function on off on off off 12 Sunshine position 0 100 50 13 Wind function 14 Automatic wind function on off on off off 15 Wind rotation direction Up down...

Page 13: ...tion direction on off off 23 Connectivity test 24 Connect with radio code 25 End point setting for RADEMACHER tubular motors via radio 26 Reset via radio 3 stage 27 Single button operation 28 Jog mode 29 Venetian blind mode on off off 30 Standard slat position 0 100 0 31 Automatic tilt after manual stop direction Down on off on 32 Automatic tilt to sunshine position on off off 33 Automatictilttove...

Page 14: ...ch button on site Input voltage 230 V 50 Hz Ri 200 kW Potential free relay contacts rotation direction s t Maximum switching capacity for a 230 V 50 Hz relay contact voltage 6 5 A 1500 W per channel Ohmic load e g bulbs 6 5 A 1500 W Inductive loads such as fluorescent lamps motors iron core transformers e g for extra low voltage bulbs such as halogen bulbs 5 A 1150 W M ...

Page 15: ...age bulbs such as halogen bulbs LEDs etc 5 A 1150 W Maximum switching capacity for a DC relay contact voltage Ohmic loads up to 30 V up to 48 V up to 100 V up to 200 V up to 300 V 6 5 A 1 5 A 0 5 A 0 3 A 0 2 A Inductive loads DC13 category max 1 A at 24 V Capacitive loads i The maximum current inrush current of capacitive loads must not exceed the current of the ohmic loads mentioned above 6 Techn...

Page 16: ...ral information Permissible ambient temperature 20 C to 55 C Dimensions W x H x D 48 7 x 45 7 x 19 8 mm Connecting terminals Spring resistance connecting terminals 0 1 mm2 1 5 mm2 Improper use can lead to serious injuries or property damage Small contact distance µ not suitable for disconnecting the device Do not use the DuoFern Motor Actuator 9471 2 to disconnect the connected appliance 6 Technic...

Page 17: ...oned on page 11 TheDuoFernMotorActuator9471 2issuitableforswitchingmains voltage basic insulated extra low voltage ELV and separated extra low voltage SELV Operating conditions Only use the DuoFern Motor Actuator 9471 2 in dry rooms A 230 V 50 Hz power supply together with a site provided disconnecting device fuse must be available at the installation location The installation and operation of the...

Page 18: ...equire additionalsafetyequipment Observetherespectivestatutory regulations for the installation of such systems Using the DuoFern Motor Actuator 9471 2 for any other purpose than previously mentioned is not permissible 7 1 Intended use A separate power supply e g mains adapter may be needed to supply power to the motor used During installation pay attention to the respective operating and installa...

Page 19: ... the DuoFern Motor Actuator 9471 2 in a roller shutter box outside or in damp rooms i 7 3 Expert knowledge required by the installer The electrical connection installation and commissioning of the DuoFern Motor Actuator 9471 2 must only be carried out by a qualified electrician in accordance with the instructions in this manual i 7 2 Improper use ...

Page 20: ...hat the voltage frequency on the type plate corresponds to that of the local mains supply DANGER There is a risk of fatal electric shock when touching electrical components All connection and installation work must only be carried out in a de energised state Disconnect all phases of the mains power lead and secure it to prevent any reconnection Check that the system is de energised ATTENTION A def...

Page 21: ...the same phase L The maximum length of lead to connect an external roller shutter switch button must not exceed 10 m i Length of insulation stripped 9 mm All wires must be stripped to 9 mm Further installation instructions In order to ensure optimal operation the DuoFern Motor Actuator 9471 2 should not be installed on a metallic base or near metal objects The DuoFern Motor Actuator 9471 2 is inte...

Page 22: ...tion on all leads down to 9 mm as specified above and connect them according to the following connection diagram 4 InserttheDuoFernMotorActuator9471 2intotheflush mounted boxandlaytheconnectingcablesaswellastheantennainthebox 5 Finally install the cover of the flush mounted box and switch on the mains power supply again 8 2 Connecting and installing the DuoFern Motor Actuator 9471 2 ...

Page 23: ...am e g for 24V DC motors N PE L 230 V 50 Hz RADEMACHER STATUS 9471 2 DuoFern Motor Aktor DC M 24 V DC L N E Made in Germany External roller shutter switch Control input Up DC motor Rotation direction Down Up i Control input Down ...

Page 24: ...tton of the DuoFern Motor Actuator 9471 2 3 The actuator then transmits either a log on or log off signal Log on log off mode remains active for 120 seconds 4 If the log on log off process is successful the STATUS LED will light up green constantly 5 Log on log off from the next DuoFern transmitter To do so repeat steps 1 to 3 or else terminate the log on log off process Observe the STATUS LED The...

Page 25: ...he actuator after installation You will find the radio code on the enclosed label and on the rear side of the DuoFern Motor Actuator 9471 2 i Please note that the use of the radio code is limited to 120 minutes after switching on the power supply A detailed description on activating the radio code function can be found in the instruction manual of the DuoFern Manual Control and the HomePilot ...

Page 26: ...ights up red 2 All of the settings are deleted and reset to the default factory settingsandthelogged onDuoFerntransmittersareautomatically logged off 3 The DuoFern Motor Actuator 9471 2 is then reset to the default factory settings A reset can be carried out to reset the DuoFern Motor Actuator 9471 2 to the default factory settings ...

Page 27: ...ins power lead and secure it to prevent any reconnection Check that the system is de energised 1 Log the DuoFern Motor Actuator 9471 2 off from the DuoFern network 2 Ensure the mains power is current free and open the flush mounted box 3 Disconnect the DuoFern Motor Actuator 9471 2 and completely remove it from the flush mounted box i ...

Page 28: ...EMACHER Geräte Elektronik GmbH hereby declares that the DuoFern Motor Actuator 9471 2 complies with the Directive 2014 53 EU Radio Equipment Directive The full text of the declaration of conformity is available at the following website www rademacher de ce ...

Page 29: ...29 EN i 13 Warranty terms and conditions You can find information about the warranty conditions of our products on our homepage ...

Page 30: ...30 EN i ...

Page 31: ...31 EN i ...

Page 32: ...RADEMACHER Geräte Elektronik GmbH Buschkamp 7 46414 Rhede Germany Subject to technical modifications misprints and errors Illustrations not binding ...

Reviews: