6.3  Description of the functions and parameters

Setting the intermediate value (1- 99%)

There are two ways to set the intermediate value.

 

If the “Save intermediate value for a manual stop” function is 
activated (factory setting), the current value configured by a 
stop command during dimming is saved as a new interme-
diate value.

 

In the configuration view of the DuoFern 1-10V Controller 
through the HomePilot®.

Random function (presence simulation)

The DuoFern 1-10V Controller can process random function 
switching commands. If a switching command is received which 
is to be delayed by the random function, then processing of the 
switching command is delayed by up to 30 minutes. 
During the delay time, the indicator light on the DuoFern 1-10V 
Controller flashes green every second.

i

 

  Automatic movement commands of the auto-

matic 
 

sun function are

 not 

delayed.

 

  Automatic switching times and dusk 

 

commands are delayed.

Stairway function (on / off) 

When the stairway function is active, the DuoFern 1-10V Controller 
will switch off the controlled device again after the configured 
“stairway time”. A switch-off advance warning can optionally be 
switched on.

Summary of Contents for 3500 12 62

Page 1: ...VBD 624 2 01 21 Item no 3500 12 62 EN DuoFern 1 10V Controller 9482 Instruction manual for the electrical connection and for commissioning Type 9482 ...

Page 2: ...ting buttons and indicator light 12 6 Functional description 13 6 1 Description of the 1 10V interface 14 6 2 Functional characteristics 16 6 3 Description of the functions and parameters 18 7 Technical specifications 21 8 Connecting the DuoFern 1 10V Controller 24 8 1 Safety instructions for the electrical connection 24 8 2 Important information regarding the electrical connection 26 8 3 Connecti...

Page 3: ...s i 10 Manual mode 31 10 1 Operation with an external button 32 10 2 Jog mode 32 11 Deleting all settings reset 33 12 Dismantling 33 13 Simplified EU declaration of conformity 34 14 Warranty terms and conditions 34 ...

Page 4: ...ruction manuals of the accessories if available as well as the instructions of the respective con nected appliance This manual is part of the product Please store it in an easily accessible place WhenpassingtheDuoFern1 10VControllerontoathirdparty this manual must be passed on as well Damage resulting from non compliance with these instruc tions and safety instructions will void the guarantee We a...

Page 5: ...dangerous situation 2 1 Levels of danger and signal words DANGER This hazard will lead to serious injury or death if not avoided WARNING WARNING This hazard may result in serious injury or death if not avoided CAUTION This hazard may result in minor or moderate injury if not avoided ATTENTION This hazard may lead to property damage i ...

Page 6: ...6 EN 2 2 Symbols and depictions used Depiction Description 1 Procedures 2 Itemisation 1 or a Lists i Further useful information Please read the respective manual i ...

Page 7: ...e page 36 3 1 Intended use Only use the DuoFern 1 10V Controller for connecting and con trolling Active electronic ballasts or power supplies with a 1 10V interface for dimming and controlling lighting Power supplies with a 1 10V interface to control other external devices e g pumps fans or blowers Operating conditions Only use the DuoFern 1 10V Controller in dry rooms A 230 V 50 Hz power supply t...

Page 8: ...se the DuoFern 1 10V Controller to disconnect the connected ballasts Never use the radio system e g DuoFern radio system and its components for the remote control of devices and systems with increased safety relevant requirements or where there is an accident risk Applications of this kind require additional safety equipment Observe the respective statutory regula tions for the installation of suc...

Page 9: ...R radio technology for controlling compatible products WR ConfigTool RADEMACHERsoftwareforprogrammingtheDuoFernmanual central operating unit incl automatic software update for the DuoFern manual central operating unit HomePilot The HomePilot is a central controller unit for RADEMACHER radio products Electronic ballast An electronic ballast for example to control LEDs and fluo rescent lamps The Duo...

Page 10: ...10 EN i 4 Included in delivery Included in delivery a 1 x DuoFern 1 10V Controller 9482 incl antenna b 1 x instruction manual not illustrated a ...

Page 11: ...230V 50 Hz Connection of an external switch button for manual control on site 2 1 10V interface Connection of the 1 10V interface of an active electronic ballast 3 Power supply for electronic ballasts Output for the 230 V electronic ballast power supply 4 230V 50 Hz Supply voltage 3 ...

Page 12: ...tus display green flashing constantly lit up brief flashing Connection is active Connection or disconnection was successful Control command received red flashing permanently lit up Disconnection is active Connection or disconnection was not successful 7 Disconnect button Logging off from the DuoFern radio net work or a DuoFern transmitter Reset to the default factory settings 5 6 7 ...

Page 13: ...econds after reaching 0 Control of external devices with a 1 10V interface External devices with a 1 10V DC interface e g pumps fans or blowers etc can also be connected and controlled Use in the DuoFern network The DuoFern 1 10V Controller can be integrated into a DuoFern network for example to use the range of functions of DuoFern sensors and DuoFern transmitters such as the HomePilot Manual ope...

Page 14: ...oller are interconnected via a polarised two core control cable The connection principle i RADEMACHER STATUS DuoFern 1 10V Steuergerät 9482 L N 1 10V L N E Made in Germany 230 V 50 Hz supply voltage DuoFern 1 10V Controller 9482 Control lead 1 10 V DC Connected to a 230 V 50 Hz supply voltage Fluorescent lamps LEDs pumps fans etc Active electronic ballast Second electronic ballast connected in par...

Page 15: ...ad is isolated from the mains lead The voltage on the control lead is a safety extra low voltage SELV The control voltage is generated by the electronic ballast The DuoFern 1 10V Controller serves as an adjustable resistor sink Several electronic ballasts can be connected in parallel to the DuoFern 1 10V Controller ...

Page 16: ...alue range Factory setting A B C D E F G 1 Manual operation On Off Dim 2 Direct configuration of a value 0 100 3 Manual mode on off on off off 4 Automatic timer on off on off on 5 Random function 6 Dawn function 7 Automatic dawn function on off on off off 8 Automatic dusk function 9 Automatic dusk function on off on off off 10 Sun function 11 Automatic sun function on off on off off The WR ConfigT...

Page 17: ... F G 12 Dimming speed 1 s 150 s 5 s 13 Intermediate value function on off off 14 Intermediate value 1 99 80 15 Unit light mode Unit light mode Light mode 16 Connectivity test 17 Connect with radio code 18 Reset via radio 3 stage 19 Single button operation 20 Jog mode 21 Stairwell function on off off 22 Stairway time pulse duration 100 ms 3276 s 3 minutes The WR ConfigTool software can be downloade...

Page 18: ...omePilot or the manual control Intermediate value function on off If the intermediate value function is activated the configured intermediate value is set first with an UP command If you press UP again the value is set to 100 The DOWN command works in a corresponding manner i This function can be set with the HomePilot Setting the intermediate value for a manual stop on off This parameter can be u...

Page 19: ...troller can process random function switching commands If a switching command is received which is to be delayed by the random function then processing of the switching command is delayed by up to 30 minutes During the delay time the indicator light on the DuoFern 1 10V Controller flashes green every second i u Automatic movement commands of the auto matic sun function are not delayed u Automatic ...

Page 20: ...t and device mode the behaviour of the DuoFern 1 10V Controller can be changed The range of functions changes as follows Switching commands of an external DuoFern transmitter Device mode Light mode UP On Off STOP Off Off DOWN Off On Dawn function On Off Automatic dusk function Off On Sun function Off i ...

Page 21: ...ch button on site Input voltage 230 V Ri 200 kW Potential free input 1 10V interface Control voltage DC 1 10 V Loading capacity Max 60 mA in total Overload protection active from 70 mA red LED active Maximum number of elec tronic ballasts Depending on the load of the individual ballasts Connection type Several ballasts can be connect ed in parallel ...

Page 22: ...A 1500 W Fluorescent lamps 5 A 1150 W Extra low voltage bulbs e g halogen bulbs LEDs etc through electronic or iron core transformers 5 A 1150 W Improper use can lead to serious injuries or property damage Small contact distance µ not suitable for disconnecting the device Do not use the DuoFern 1 10V Controller to disconnect the connected ballasts ...

Page 23: ...with medium time lag or with time lag Permissible ambient temperature range 0 C to 40 C Dimensions W x H x D 48 7 x 45 7 x 19 8 mm Connecting terminals Spring resistance connecting ter minals 0 1 mm2 1 5 mm2 Data storage after a power failure All data is retained in the event of a power failure Only the configured brightness value is lost TheconnectedapplianceisalwaysswitchedoffwhentheDuoFern 1 10...

Page 24: ...electri cal components All connection and installation work must only be carried out in a de energised state Disconnect all phases of the mains power lead and secure it to prevent any reconnection Check that the system is de energised Priortotheelectricalconnection checkthatthevoltage frequen cy on the type plate corresponds to that of the local mains supply i i ...

Page 25: ...allast load 230 V 50 Hz output load contact L The maximum switching capacity must not be exceeded Please observe the details in the technical specifications see page 22 ATTENTION Connecting the 1 10V control lead with the incorrect polari ty can destroy the device Pay attention to the correct polarity when connecting the 1 10V control lead ATTENTION A defective antenna can cause malfunctions or th...

Page 26: ...ed The maximum length of lead to connect an external button must not exceed 10 m Minimum length of insulation stripped 9 mm All leads must be stripped to 9 mm Further installation instructions In order to ensure optimal operation the DuoFern 1 10V Controller should not be installed on a metallic base or near metal objects The DuoFern 1 10V Controller is intended for flush mounting We recommend ins...

Page 27: ...emove the insulation on all leads as specified above and con nect them according to the following connection diagram 4 Insert the DuoFern 1 10V Controller into the flush mounted box and lay the connecting cables as well as the antenna in the box 5 Finally install the cover of the flush mounted box and switch on the electricity again 8 3 Connecting and installing the DuoFern 1 10V Controller ...

Page 28: ...uoFern 1 10V Steuergerät 9482 L N 1 10V L N E Made in Germany 1 10 V 230 V L N N L 230 V 50 Hz 230 V 50 Hz External button 1 10 V control lead Connected to 230 V 50 Hz Active elec tronic ballast or LED power supply Fluorescent lamp LED pump fan etc i ...

Page 29: ...on of the DuoFern 1 10V Controller 3 The DuoFern 1 10V Controller then transmits either a log on or log off signal Log on log off mode remains active for 120 seconds 4 If the log on log off process is successful the STATUS LED will light up green constantly 5 Log on log off from the next DuoFern transmitter To do so repeat steps 1 to 3 or else terminate the log on log off process Observe the STATU...

Page 30: ...0VControllerafterinstallation You will find the radio code on the enclosed label and on the rear side of the DuoFern 1 10V Controller i Please note that the use of the radio code is limited to 120 minutes after switching on the power supply A detailed description on activating the radio code function can be found in the instruction manual of the DuoFern Manual Control and the HomePilot ...

Page 31: ...awn function 100 0 Automatic dusk function 0 100 Sun programme 0 0 UP with current dimming direction 100 100 STOP UP with current dimming direction 0 STOP 0 STOP with current dimming direction 100 STOP STOP STOP with current dimming direction 0 STOP STOP DOWN with current dimming direction 100 STOP 100 DOWN with current dimming direction 0 0 STOP ...

Page 32: ...e Use the light mode if you want to operate the DuoFern 1 10V Controller together with roller shutters 10 1 Operation with an external button Brief press switches ON OFF does not stop upon reaching the intermediate state Press and hold dims alternately on to 100 off to 0 the new dimmed value is saved as the intermediate value 10 2 Jog mode Jog mode is available to conveniently configure the output...

Page 33: ... settings A reset must be carried out to reset the DuoFern 1 10V Controller to the default factory settings 12 Dismantling DANGER There is a risk of fatal electric shock when touching electri cal components Disconnect all phases of the mains power lead and secure it to prevent any reconnection Check that the system is de energised 1 Log the DuoFern controller off from the DuoFern network 2 Ensure ...

Page 34: ...tallation instructions All construction faults material de fects and manufacturing defects shall be covered by the warranty Yourstatutorywarrantyclaimsremainunaffectedbythiswarranty The following are not covered by the warranty Incorrect fitting or installation Non observance of the installation and operating manual Improper operation or wear and tear External influences such as impacts knocks or ...

Page 35: ...e invoice RADEMACHER will remedy any defects that occur within the war ranty period free of charge either by repair or by replacement of the affected parts or by supplying a new replacement unit or one to the same value There is no general extension of the original warranty period by delivery of a replacement or by repair as per the terms of the warranty 14 Warranty terms and conditions i ...

Page 36: ...her de Service Hotline 01807 933 171 Fax 49 2872 933 253 service rademacher de Subject to technical modifications misprints and errors excepted Illustrations not binding 30 seconds free of charge subsequently 14 cents minute from German fixed line networks and max 42 cents minute from German cellular networks ...

Reviews: