5. Serial Port Communication Port
In normal working state, you can control the camera through RS-232/RS-485
(VISCA IN) cable. The parameters of RS-232 are as below:
Baud rate: 2400/4800/9600/115200/second
Start Bit: 1 bit;
Data Bit: 8 bit;
Stop Bit: 1 bit;
Verification Bit: None.
After powering on, the camera runs a self-check and then returns back to its
center position. The zoom lens is extended to the farthest position and then
pulled back. The self-check is completed at that point.
The camera will apply preset 0 after initialization completes if it is configured.
The user can control the device using serial commands.
5.1 VISCA Protocol List
5.1.1 Camera return command Ack/Completion Message
Command Message
ACK
Completion
Command packet
z0 41 FF
z0 51 FF
Remark
Returned when the command is accepted.
Returned when the command has been
executed.
24