Note
1.
Port 443 and 8889 are used internally for service access. Exercise caution when
making rules which may affect datagrams to/from this port in Firewall settings.
Connection between your PC and RipEX may be lost. When this happens, use the
Reset button on the bottom side of RipEX (keep it pressed for 15 sec.) in order to
set Default access, which restores the default Ethernet IP, default password, sets
the Firewall to Off, sets ARP proxy&VLAN settings to Off and Ethernet speed to
Auto.
2.
Firewall settings do not impact packets received and redirected from/to Radio
channel.
Alarm management
The average values of parameters listed in the table (Watched values) are continuously monitored.
When any of them exceeds the respective threshold, the selected action(s) is(are) invoked.
Fig. 7.4: Menu Alarm management
Note
At least 10 values have to be included on average before it is checked for the possible
alarm. Since different values are sampled over different periods, different times are required
to obtain correct values:
Ucc, Temp – approx. 10 sec. after booting
PWR, VSWR - approx. 10 sec. after booting and after the first transmission
Others – approx. 200 sec. of respective communication
•
Threshold
List box: Default, Manual,
Default = Default
Default
– Default (recommended) values are set and can not be edited.
85
© RACOM s.r.o. – RipEX Radio modem & Router
Advanced Configuration