4. Table of Technical Parameters
Tab. 4.1: Technical parameters
RE400: 373.25–484 MHz
Frequency range
25 kHz or 12.5 kHz or 6.25 kHz *
Channel bandwith
5 kHz or 6.25 kHz
Frequency step
software
Method of setting working frequency
< 1.5 ms
Rx/Tx switching time
32 bit CRC
Data security on RF channel
better than -107 dBm
Receiver sensitivity for BER 10
-3
0.5 W
Low
Output power software
adjustable
2 W
High
2.6 kbps in 6.25 kHz channel *
Data rate in RF channel
5.2 kbps in 12.5 kHz channel
10.4 kbps in 25 kHz channel
Ethernet, RS232
Interfaces
SMA
Antenna connector
>100 000 hodin
MTBF (Mean Time Between Failures)
PoE
AUX
Power method
38–57 V
10.8–30 V (nomin. 13.8 V)
Power supply
145 mA/48 V
430 mA/13.8 V
Idle state (Rx)
Power
consumption
(cca)
230 mA/48 V
700 mA/13.8 V
Low power Tx
310 mA/48 V
950 mA/13.8 V
High power Tx
-25 až +55 °C
Operating temperature range
-35 až +85 °C
Storage temperature range
137 × 96 × 31 mm
Case dimensions
0.3 kg
Weight
*
Channel spacing 6.25 kHz is not approved under EU rules.
Tab. 4.2: Standards complied with
ETSI EN 300 113-2 V 1.6.1
Radio parameters
ETSI EN 301 489-1 V1.6.1
EMC (Electromagnetic Compatibility)
CENELEC EN 60 950 ed.2:2006; EN 50 385;
EN 50 383
Electrical safety
Narrowband radio modem ECONOMY RE400 – © RACOM s.r.o.
24
Table of Technical Parameters