Rackable Systems S3118 User Manual Download Page 6

 

Figure 4: Hard drive carrier locations for two eight-port RAID server configurations 

If you also have drives labeled “B0” and/or “B1” these should go into the two rear-accessible drive bays 
from left to right.

 

2.3.2.3 

Single 16-port RAID Card Configuration 

Systems configured with a single sixteen port RAID card are set up differently. In that case, there will be a 
single number on the carrier from 0 to 15 indicating the position in the array. Install these as follows 
(figure 5): 

 

Figure 5: Hard drive carrier locations for one sixteen-port RAID server configurations 

If you also have drives labeled “B0” and/or “B1” these should go into the two rear-accessible drive bays 
from left to right.

 

2.3.2.4 

Verifying Correct Drive Seating 

Regardless of which drive configuration your system includes, please verify that the drives are fully 
inserted before powering on the system. When powering on the server for the first time, verify that the 
yellow power LEDs on all drive carriers light up. If a drive power indicator doesn’t light up on power on, 
verify that the drive is correctly inserted in the carrier and try again. 

2.4  Moving the S3118 Within/Between Racks 

If you later need to move the S3118 server, please carefully remove all drive carriers from the unit prior to 
moving the unit. Once you have re-racked the server in the new location, reinsert the drives into their 
original locations as shown above. This will minimize the risk of damaging the drives and/or drive 
backplanes while the system is moved. 

3 System 

Interface 

3.1  Front I/O Panel 

 

Figure 6: S3118 I/O Panel 

12 

13 

10 

14 

11 

15 

0-0 

0-1 

0-2 

0-3 

0-4 

0-5 

0-6 

0-7 

1-0 

1-1 

1-2 

1-3 

1-4 

1-5 

1-6 

1-7 

S3118-Manual-1.0.1 

June 30, 2005 

Page 6 of 15 

 

Summary of Contents for S3118

Page 1: ...Rackable Systems S3118 3U STORAGE SERVER USER S MANUAL Revision 1 0 1 S3118 Manual 1 0 1 June 30 2005 Page 1 of 15...

Page 2: ...rier I O 7 3 3 Rear I O Panel 7 4 RAID Configuration 7 4 1 Configuring Hardware RAID 8 4 2 Configuring Software RAID 8 5 Software Installation and Tuning 9 5 1 NAS Appliance Configuration 9 5 2 iSCSI...

Page 3: ...thermal design utilizing four hot swappable system fans The system design assures a uniform and adequate flow of cooling air to be drawn over the entire motherboard hard drive memory and CPU area at...

Page 4: ...proximately 30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing 2 2 2 Rack Precautions Ensure that the leveling jacks on the bottom of the rack are ful...

Page 5: ...ce the server is installed in the rack you will need to insert the drive carriers into the chassis The drives are labeled differently depending on what RAID cards are included in your system configura...

Page 6: ...guration your system includes please verify that the drives are fully inserted before powering on the system When powering on the server for the first time verify that the yellow power LEDs on all dri...

Page 7: ...gement The red LED on the right is a management fault indicator light that is controlled via the remote management card 3 1 3 LCD and Remote Management Serial Port On the far left side of the I O pane...

Page 8: ...06 series cards you will need to press alt 3 again after leaving the first card s configuration screen to configure the second array Follow the instructions to create the RAID partition of your choice...

Page 9: ...rs with no client access licenses required Automatic shutdown on power failure when connected to APC SmartUPS battery backup Redundant mirrored OS partition on rear accessible swappable drives Email a...

Page 10: ...performance and still significantly better than ext3 for large file streaming performance whereas XFS is generally seen as better at large file streaming performance than small file performance The R...

Page 11: ...inux clients modify etc sysctl conf as follows to improve large file single stream performance net core rmem_max 262143 net core wmem_max 262143 net core rmem_default 262143 net core wmem_default 2621...

Page 12: ...all the drivers appropriate for the RAID card s in your server available for free download from the RAID card manufacturer s web site Make sure that the drivers you download are compatible with the cu...

Page 13: ...inted circuit boards or areas where power is present After accessing the inside of the system close the system back up and secure it to the rack unit with the retention screws after ensuring that all...

Page 14: ...System four swappable 80mm fans Fans are serial redundant for high availability Form Factor 3U rack mount standard depth 27 3 Dimensions 19 x 5 25 x 27 3 in W x H x D Weight Gross Full System 85 lbs A...

Page 15: ...s Rackable Systems Inc 1933 Milmont Dr Milpitas CA 95035 USA Tel 1 408 321 0290 Fax 1 408 321 0293 Email sales rackable com General Information support rackable com Technical Support Web Site http www...

Reviews: