NO.TCA-05
2014.11.17
3
2
1
Adjusting of photo sensor for tape cutter :
1. The reflection plate is adhered on machine bed under sensor .
(At left side of presser foot and between needle and cutter.)
2. Adjusting of photo sensor : The distance between sensor and
reflection plate must be at least 4cm .Sensor LED must
be light up when sensor aims at reflection plate. Please adjust
the sensor position and angle. If the sensor LED is either sparkly
or light off which means the position is not accurate, re-adhere the
reflection plate to adjust position if necessary.
2
3
2
:
4cm
3
INSTALLATION GUIDE
4
Adjusting of Auto Tape Cutter with Photo Sensor unit
Operation guide of Reset Switch for Auto Cutter
Operation guide : Push this button (Figure 1) to reset the process when operator is facing theimproper
operation ( Such as Thread broken.) If the LED is Light ON which is mean cutter
isready to act, it is very important to push this button to reset the process before
starting sewing after re-run the material.
(Otherwise, the cutter will be acted by stitch counter automatically.)
1
4
2
1
2
1
2
2
Remark : Tear off the membrane on reflection plate before using.
5 pcs of reflection plates are included as spare parts.
Reset Switch for Auto Cutter
Figure 1)
LED FOR CUTTER STITCH COUNTER
4cm
at least 4cm
3
1
Reflection plate
2
Sensor
Sensor LED
4