d.  Hose connection 

The pump is equipped with a universal fitting which allows connecting hoses of various sizes as listed 
below: 

 

 

 
 

Connection for hoses of Ø 13 mm / 15 mm / 19 mm: 
Cut off the topmost nipple on the universal fitting at the position○,a. 
Screw a 25.4 mm tap adaptor onto the universal fitting. 
Connect a hose quick connector (for hose of Ø 13 mm or 15 mm or 19 mm) to the tap adaptor, 
then insert the hose and tighten it. 

 

Connection for hose of Ø 25 mm: 
Screw and push a hose of Ø 25 mm onto the universal fitting without cutting anything. 
Tighten the hose with a hose clamp. 

 

Connection for hose of Ø 32 mm: 
Cut off top two nipples on the universal fitting at the position ○,b 
Screw and push a hose of Ø 32 mm onto the universal fitting. 
Tighten the hose with a hose clamp. 
 

 

Note: hose, tap adaptor, hose quick connector and hose clamp are not provided. 

 
e.  Starting  

 

Check that the pump is at the bottom of the well. 

Check if the pipe is correctly fixed; diameter minimum 1 "1/4. 

Make sure that the connection to the mains is never reached by moisture or water. 

Do not allow the pump to run dry. 
 

Venting the pump before use 

Always ensure that the pump is vented properly before commissioning the pump. Possibly tilting 
back and forth several times until no more air  bubbles appear,  wait at least  15  seconds before 
the pump to start. 

 

Setting the ON/OFF operating point 

The ON and OFF operating point of the float switch can be set by adjusting the float switch in its 
latching holder. 

Before putting the pump into operation, please check the following: 

 

The float switch must be installed so that the level of the ON operating point and the level of 
the OFF operating point can be reached easily and with little force. To check this, place the 
pump in a vessel filled with water, raise the float switch carefully by hand and then lower it 
again. As you do so, note whether the pump switches on and off. 

Summary of Contents for RAY400EPDW

Page 1: ...RIGINAL INSTRUCTIONS INSTRUCTIONS MANUAL SUBMERSIBLE PUMP 400W RAY400EPDW CAUTION Read these instructions before use this appliance BUILDER 32 rue Aristide Berg s ZI 31270 Cugnaux France MADE IN PRC 2...

Page 2: ...not use attachments other than those recommended by the manufacturer they can damage the unit and or cause injury DANGER OF SUFFOCATION Keep packaging materials out of the reach of children Before an...

Page 3: ...e This submersible motor pump is designed for the discharge of water at a maximum temperature of 35 C This pump should not be used for the discharge of other liquids particularly motor fuels cleaning...

Page 4: ...ing handle 2 Supply cord 3 Water outlet 4 Water inlet 5 Floating switch 6 Motor housing b Technical data Type RAY400EPDW Voltage frequency 230V 50Hz Power input 400W Delivery rate max 7500 l h Max tot...

Page 5: ...ing and humidity Avoid the discharge of aggressive liquids and the discharge of abrasive materials Warning When installing the pump attach the pump with its handle do not use other parts of the applia...

Page 6: ...e Starting Check that the pump is at the bottom of the well Check if the pipe is correctly fixed diameter minimum 1 1 4 Make sure that the connection to the mains is never reached by moisture or wate...

Page 7: ...fluff and fibrous particles which may have deposited in the pump casing with a jet of water Every three months remove the mud from the bottom of the well and clean the walls of the well Remove the dep...

Page 8: ...not switch off Floater cannot sink down Place pump properly on shaft ground Insufficient flow Inlet sieve is clogged Reduced pumping capacity by dirty and abrasive water Clean inlet sieve Clean pump...

Page 9: ...9...

Reviews: