Basic
Functional
Check
The functional check consists of checking the 1264C power supply
voltages to the VXIbus limits at the P1 and P2 connectors using a
digital voltmeter.
Referring to Tables 3-2 to 3-5 and Figure 3-1 connect one lead of
the voltmeter to a supply pin. Connect the reference lead of the
voltmeter to one of the ground pins. Compare each voltage
reading to the values listed in Tables 3-5.
Table 3-5 Power Supply Voltages at the P1 and P2 Connectors
P1/P2
Measurement
Location (PIN)
Supply
VXI Acceptable
Voltage Range
P1-C32
+5V
4.875V to 5.25V
P1-A31
-12V
-12.6 to 11.64V
P2-C32
-24V
-25.2V to -23.28V
P2-C13
-2V
-2.1V to -1.9V
P1-C31
+12V
11.64V to 12.6V
P2-C31
+24V
23.28V to 25.2V
P2-C4
-5.2V
-5.46V to -5.044V
P1-C9, P2-C3
Logic Ground
If the voltages are within the specified ranges, the mainframe
complies with the VXI voltage limit specifications.
Note that the “Voltage Range” values in Table 3-5 are identical to
the VXIbus Specification. The voltage range limits provided in
Table 3-1 refer to the voltage monitor indicators on the 1264C
front panel. The monitor will detect a voltage error when the limit is
exceeded (V
nominal
±
10% V
nominal
±
4% accuracy).
Summary of Contents for 1264C
Page 5: ......
Page 6: ...This page was left intentionally blank ...
Page 12: ...vi This page was left intentionally blank ...
Page 57: ...1264C User Manual Racal Instruments 1998 Maintenance 5 15 ...
Page 58: ...1264C User Manual Maintenance 5 16 Racal Instruments 1998 ...
Page 59: ...1264C User Manual Racal Instruments 1998 Maintenance 5 17 ...
Page 60: ...1264C User Manual Maintenance 5 18 Racal Instruments 1998 ...
Page 61: ...1264C User Manual Racal Instruments 1998 Maintenance 5 19 ...
Page 62: ...1264C User Manual Maintenance 5 20 Racal Instruments 1998 ...
Page 63: ...1264C User Manual Racal Instruments 1998 Maintenance 5 21 ...
Page 64: ...1264C User Manual Maintenance 5 22 Racal Instruments 1998 ...
Page 65: ...1264C User Manual Racal Instruments 1998 Maintenance 5 23 ...
Page 66: ...1264C User Manual Maintenance 5 24 Racal Instruments 1998 ...
Page 67: ...1264C User Manual Racal Instruments 1998 Maintenance 5 25 ...
Page 68: ...1264C User Manual Maintenance 5 26 Racal Instruments 1998 SLOT 5 ...
Page 69: ...1264C User Manual Racal Instruments 1998 Maintenance 5 27 ...
Page 70: ...1264C User Manual Maintenance 5 28 Racal Instruments 1998 ...
Page 71: ...1264C User Manual Racal Instruments 1998 Maintenance 5 29 ...
Page 72: ...1264C User Manual Maintenance 5 30 Racal Instruments 1998 ...
Page 73: ...1264C User Manual Racal Instruments 1998 Maintenance 5 31 ...
Page 74: ...1264C User Manual Maintenance 5 32 Racal Instruments 1998 ...
Page 75: ...1264C User Manual Racal Instruments 1998 Maintenance 5 33 ...
Page 76: ...1264C User Manual Maintenance 5 34 Racal Instruments 1998 ...
Page 77: ...1264C User Manual Racal Instruments 1998 Maintenance 5 35 ...
Page 78: ...1264C User Manual Maintenance 5 36 Racal Instruments 1998 ...
Page 79: ...1264C User Manual Racal Instruments 1998 Maintenance 5 37 ...
Page 80: ...1264C User Manual Maintenance 5 38 Racal Instruments 1998 ...
Page 81: ...1264C User Manual Racal Instruments 1998 Maintenance 5 39 ...
Page 82: ...1264C User Manual Maintenance 5 40 Racal Instruments 1998 ...
Page 83: ...1264C User Manual Racal Instruments 1998 Maintenance 5 41 ...
Page 84: ...1264C User Manual Maintenance 5 42 Racal Instruments 1998 ...
Page 85: ...1264C User Manual Racal Instruments 1998 Maintenance 5 43 ...