1260-82 User Manual
Module Operation 3-14
4. Plot the 1260-82 operating point (Pressure, Airflow) against the
chassis cooling curve. If the module operating point lies under
the chassis curve, the module should remain within the
specified temperature. An example of a 1260-82 Module in a
Racal 1261B VXI Chassis is shown in Figure 3-4. The
chassis airflow plotted is for the “worst case” slot airflow. In
the 1261B chassis, the 1260-82 could be placed in any slot
without much concern for the temperature rise of 10
°
C being
exceeded.
CAUTION
The required airflow may need to be increased
depending on airflow distribution across the module,
the ambient temperature and reliability issues. Consult
the VXI specification for more details.
Summary of Contents for 1260-82
Page 4: ...This page was left intentionally blank...
Page 8: ...1260 82 User Manual iv This page was left intentionally blank...
Page 20: ...1260 82 User Manual Installation Instructions 2 8 This page was left intentionally blank...
Page 36: ...1260 82 User Manual Module Operation 3 16 This page was left intentionally blank...
Page 38: ...1260 82 User Manual Drawings 4 2 This page was left intentionally blank...
Page 40: ...1260 82 User Manual Drawings 4 4...
Page 47: ...1260 82 User Manual Drawings 4 11...
Page 60: ...1260 82 User Manual Drawings 4 24 This page was left intentionally blank...
Page 62: ...1260 82 User Manual Parts List 5 2 This page was left intentionally blank...
Page 70: ...1260 82 User Manual Parts List 5 10 This page was left intentionally blank...